Replicating The Setup; Copying To Single Workstation; Copying To Multiple Workstations - HP xw3400 - Workstation Technical Reference Manual

Hp xw3400 workstation - service and technical reference guide
Hide thumbs Also See for xw3400 - Workstation:
Table of Contents

Advertisement

If the system successfully reprograms the ROM, the system will automatically power off.
Remove the removable media used to upgrade the BIOS.
4.
Turn the power on to restart the workstation.
5.

Replicating the setup

The following procedures give an administrator the ability to easily copy one setup configuration to other
workstations of the same model. This allows for faster, more consistent configuration of multiple
workstations.
NOTE:
Both procedures require a diskette drive or a supported USB flash media device, such as an HP
Drive Key.

Copying to single workstation

CAUTION:
workstations are not the same model. For example, do not copy the setup configuration from a xw3400
Workstation to a xw3400 Workstation.
Select a setup configuration to copy. Turn off the workstation. If you are in Windows, click
1.
Start > Shut Down > Shut Down.
If you are using a USB flash media device, insert it now.
2.
Turn on the workstation.
3.
As soon as the workstation is turned on, press
4.
Computer Setup. Press
NOTE:
press
F10
If you are using a diskette, insert it now.
5.
Click File > Replicated Setup > Save to Removable Media. Follow the instructions on the
6.
screen to create the configuration diskette or USB flash media device.
Turn off the workstation to be configured and insert the configuration diskette or USB flash media
7.
device.
Turn on the workstation to be configured.
8.
As soon as the workstation is turned on, press
9.
Computer Setup. Press
Click File > Replicated Setup > Restore from Removable Media, and follow the instructions
10.
on the screen.
Restart the workstation when the configuration is complete.
11.

Copying to multiple workstations

CAUTION:
workstations are not the same model. For example, do not copy the setup configuration from a xw3400
Workstation to a xw3400 Workstation.
30
Chapter 4 Desktop management
A setup configuration is model-specific. File system corruption may result if source and target
Enter
to bypass the title screen, if necessary.
If you do not press
F10
when the monitor light turns green to access the utility.
Enter
to bypass the title screen, if necessary.
A setup configuration is model-specific. File system corruption may result if source and target
F10
when the monitor light turns green to enter
at the appropriate time, you must restart the workstation and again
F10
when the monitor light turns green to enter
ENWW

Advertisement

Table of Contents
loading

Table of Contents