3 Troubleshooting Your HP PC Workstation
Using HP MaxiLife to Diagnose Problems
Pre-Boot Checks
ERROR !
CPU Socket
Check that the processor is
correctly inserted in CPU slot.
ERROR !
Contin Module
Check that RDRAM
continuity modules are
installed.
Using HP MaxiLife to Diagnose Problems
Your HP LCD can help you to diagnose problems with your PC Workstation,
even when you are unable to get your system and monitor working properly.
When you press your PC Workstation's on/off button, HP MaxiLife will check
your system before it initiates the start-up sequence. The pre-boot diagnostic
tests are run in order of priority with respect to their importance to computer
functions. The first detected error displays a message on the LCD status panel.
If this happens, one of the following screens could appear.
Check the power supply and
power cable connections.
he 32 device limit per
T
RDRAM has been exceed.
ERROR !
RIMM Speed
The RDRAM modules
installed have incompatible
speed ratings.
54
ERROR !
Power Supply
ERROR !
RIMM Devices
Memory Error
Check that the memory
modules are correctly
installed.
ERROR !
Board PLL
Check that the system board is
connected.
ERROR !
No RIMM
No installed RDRAM
modules.