Scsi Termination - Adaptec Workstation x1000 Installation Manual

Ata raid; scsi raid
Hide thumbs Also See for Workstation x1000:
Table of Contents

Advertisement

Adaptec RAID Installation Guide
Host Bus Adapter window in Storage Manager to change the controller
SCSI ID.
Note: Changing the controller ID is not recommended. You
should leave the Adaptec RAID controller set at SCSI ID
7.

SCSI termination

The basics of termination are as follows:
Enable termination on the devices on each physical end of a
SCSI cable. Depending upon how you configure your
system, you would either
Enable termination on two SCSI peripheral devices, or
Enable termination on the SCSI controller and one
peripheral SCSI device.
If you are using multiple SCSI channels on a single
controller, terminate each channel separately.
SCSI termination for Adaptec SCSI RAID controllers is
configured through the SMOR utility or from the Configure Host
Bus Adapter window in Storage Manager. The controller has four
possible termination settings, as shown in the following table:
Setting
Function
Auto
Default—Used for all cabling conditions, except where
two Narrow cables are attached or both Narrow and Wide
cables are attached. For these exceptions, use High Only.
High Only
Terminates only the additional signals that are used on
Wide SCSI devices. This allows attachment of a Narrow
cable, or both a Wide and Narrow cable together, to be
attached to the controller.
Disabled
Disables controller termination unconditionally.
Enabled
Enables controller termination unconditionally.
Devices on the second bus (Bus 1) and higher (if the RAID
controller has more than two) must have Wide termination.
2-4