5022-xxx
Transfer contact assembly removal
See
"Transfer contact assembly" on page 7-11
1.
Remove the HVPS. See
2.
Remove all the inside contact springs. See
3.
Remove the four screws (A), and remove the transfer contact assembly.
4.
Remove the eight springs (B) for reuse during installation.
Note: The top spring may fall away from the transfer contact assembly during removal.
Installation note: For ease of installation, put the transfer contact assembly on before installing the springs.
A
4-92
Service Manual
for the part number.
"High voltage power supply (HVPS) removal" on page
"Contact springs removal" on page
B
B
A
B
4-62.
4-44.