FC Ping dialog box

The FC Ping dialog box
that the frame was returned.
Figure 17

FC Ping dialog box

To verify a Fibre Channel connection:
1.
Select Switch > FC Ping to open the FC Ping dialog box.
2.
Open the Destination drop-down list, and select a destination port.
3.
Select the Port WWN or Port Address option.
4.
In the Repeat area, use the arrow keys to select or type in a value (1–100) for the number of FC ping
attempts to perform.
5.
In the Timeout area, select the number of seconds (0–10) to continue attempting the FC ping operation
before timing out. Click and drag the slide bar to move the slide bar.
6.
Click Ping, and view the results in the text window.
HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Enterprise Fabric Management Suite User Guide
(Figure
17) enables you to send an ECHO frame to a specified target and verify
37