Table 1 1
Switch data window fields (continued)
Field
Services Group
NTP Client Enabled
NTP Server Address
FDMI Enable
FDMI HBA Entry Limit
Embedded GUI Enabled
Inactivity Timeout
GUI Mgmt Enabled
Telnet Enabled
SSH Enabled
SSL Enabled
CIM Enabled
FTP Enabled
Management Server Enabled
SNMP Enabled
Call Home Enabled
Zones/Security Group
Interop Mode
Legacy Address Format
Merge Auto Save
Default Zone
HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Enterprise Fabric Management Suite User Guide
Description
Enables switches to synchronize their time to a centralized server.
Enabled or Disabled.
IP address of the centralized NTP server. Ethernet connection to NTP
server is required.
Fabric Device Management Interface status. If enabled, device
information can be obtained, managed, and saved through the fabric
using Name Service Management Server functions. If FDMI is
Enabled on the entry switch, Enterprise Fabric Management Suite
reports all FDMI information reported by the entry switch.
Maximum number of HBAs that can be registered with a switch
Web applet status. Indicates whether the web applet on the switch is
Enabled or Disabled.
Number of minutes the switch waits before terminating an idle
command line interface (CLI) session. Zero (0) disables the timeout
threshold.
Web applet status. If this option is disabled, the switch cannot be
managed using the web applet.
Telnet client status Enabled or Disabled
Secure Shell status. If Enabled, an encrypted data path is provided
for command line interface sessions.
Secure Sockets Layer status. If enabled, encryption for switch
management web applet and CIM sessions is provided.
Common Interface Model status. The CIM agent is based on the
Storage Networking Industry Association (SNIA) Storage
Management Initiative Specification (SMI-S), which is the standard for
SAN management in a heterogeneous environment.
FTP status Enabled or Disabled
Management server status Enabled or Disabled
SNMP status, Enabled or Disabled
Call Home status. If enabled and configured, switches can send alerts
to pagers and email. Users can configure the type of events and
where the alerts are sent.
Standard
None
If enabled, any zoning updates from the fabric are saved in
permanent (non-volatile) memory as well as temporary memory. if
disabled, any zoning updates from the fabric are saved only in
temporary memory and are lost after a switch reset.
Enables or disables communication between ports and devices not
defined in the active zone set, or when there is no active zone set