Advanced Switch Properties (Timeout Values); Advanced Switch Properties Dialog Box - HP StorageWorks 8/20q User Manual

Hp storageworks 8/20q and sn6000 fibre channel switch enterprise fabric management suite user guide (5697-0420, june 2010)
Hide thumbs Also See for StorageWorks 8/20q:
Table of Contents

Advertisement

To view detailed FDMI information for a device, click the Devices tab, and click (i) in the Details column of
the Devices data window. The Detailed Devices Display dialog box displays the specific information for
that device. For more information, see

Advanced switch properties (timeout values)

The Advanced Switch Properties dialog box
on the switch, and is available only on the entry switch. The timeout values must be the same for all
switches in the fabric.
IMPORTANT:
switch offline to change these values.
To change timeout values:
1.
Select the entry switch in the fabric tree.
2.
Select Switch > Switch Properties to open the Switch Properties dialog box
3.
Select Offline in the Administrative State field, and click OK. When the application confirms that the
change has been applied, proceed.
4.
Select Switch > Advanced Switch Properties to open the Advanced Switch Properties dialog box
(Figure
53).
Figure 53

Advanced Switch Properties dialog box

5.
Make changes to the R_A_TOV and E_D_TOV switch timeout values:
• R_A_TOV (Resource Allocation Timeout)—The maximum time a frame could be delayed and still be
delivered. The default is 10000 milliseconds.
• E_D_TOV (Error Detect Timeout)—The maximum round trip time that an operation between two
N_Ports could require. The default is 2000 milliseconds.
6.
Click OK to put the new values into effect.
7.
Select Switch > Switch Properties to open the Switch Properties dialog box.
8.
Select Online in the Administrative State drop-down list, and click OK to place the switch back online.
9.
Repeat this procedure on every switch in the fabric to ensure that all timeout values are the same.
96
Managing Switches
"Devices data
Timeout values should not be changed unless absolutely necessary. You must place the
window" (page 39).
(Figure
53) enables you to set the timeout values for all ports
(Figure
52).