The washer
can be installed
using the standpipe
drain system (floor or wall),
the laundry
tub
drain
system, or the floor drain system.
Select the drain hose installation
method
you need.
See "Fools and Parts."
Standpipe
drain system--wall
or floor
(views A & B)
The standpipe
drain
requires
a minimum
diameter
standpipe
of 2" (5 cm). The minimum
carry-away
capacity
can be no less than 17 gal. (64 I.) per minute.
A 2" (5 cm) diameter
to
1" (2.5 cm) diameter
standpipe
adapter
kit is available.
See "lools
and Parts."
The top of the standpipe
must be at least 39" (99 cm) high and no higher
than 96" (244 cm/
from the bottom
of the washer.
39"
(99 cm)
Laundry tub drain system (view C)
lhe
laundry tub needs a minimum
20 gal. (76 [.) capacity.
The top of the laundry tub must be
at least 39" (99 cm) above the floor
and no higher than 96" (244 cm) from the bottom
of the
washer.
Floor
drain
system
(view
D)
The floor drain
system requires
a siphon
break that may be purchased
separately.
See "Fools
and Parts."
The siphon
break must be a minimum
of 28" (7I cm) from the bottom
of the washer.
Additional
hoses might be needed.
C
I!!I0(.i I'I(] i[II
I
_, /,[
//,/tf
I
¢#,[ I
1,[
/_
_
i
Electrical Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow
these instructions can result in death,
fire, or electrical shock.
A 120 volt, 60 Hz., AC only, 15- or 20-amp,
fused electrical
supply
is required.
A time-
delay fuse or circuit
breaker
is recommended.
[t is recommended
that a separate
circuit
serving
only this appliance
be provided.
This washer
is equipped
with
a power
supply
cord having
a grounded
3 prong plug.
lo minimize
possible
shock hazard,
the cord must be plugged
into a mating,
grounded
3 prong outlet,
grounded
in accordance
with
local codes and ordinances.
If a mating
outlet
is not available,
it is the personal
responsibility
and obligation
of the customer
to
have the properly
grounded
outlet
installed
by a qualified
electrician.
[f codes permit
and a separate
ground
wire is used, it is recommended
that a qualified
electrician
determine
that the ground
path is adequate.
Do not ground
to a gas pipe.
6