Controls and Accessory Installation

See wiring diagram for more information. See Wiring Specifications on p. 9 for wiring
distances and wire gauge information.
All inputs are normally open and momentary, except the stop (NC), and emergency close and
emergency open (constant pressure). The following instructions are based upon UL 325, dated March
of 1999 and include recommendations for significant increase in safety.
We strongly recommend that you follow the UL guidelines presented throughout the manual.
Installation device instructions – always follow the instructions provided by the manufacturer when
installing and adjusting any control device. If these instructions are contrary to the advice given here,
call for assistance.
WARNING
All controls that are to be used to operate the gate system must be installed where the user
cannot touch the gate while operating the controls. Also, always install the controls where the
user has full view of gate operation.
5
SUPERVISED
OPEN BUTTON
Caution - Only wired devices in sight of the
gate may be used with this input.
OPEN
5
EXTERNAL ENTRAPMENT OPEN
Will reverse (close) the gate if active. If
entrapment is sensed during a reversal, the
gate will stop. May defeat the timer to close.
5
INTERRUPT LOOP
This input is for vehicles only and does not
provide UL secondary safety for persons. This
functions as an wireless open unless on the
close limit where it is defeated - thus preventing
vehicles from entering freely.
1
2
3
RADIO
RECEIVER
NOTE: Numbers shown inside a box are on the J1 terminal strip on the circuit board.
Connections shown here are field connections. The radio receiver may be ordered factory
installed.
7
5
(WIRELESS) UNSUPERVISED
OPEN BUTTON
Any device can be used here and the radio
(R2) is wired here internally by the factory.
Note, on a second inherent obstruction, this
input will not function (disabled).
SECONDARY SAFETY
It is recommended that secondary
9
safeties always be used for both
the open and close directions.
Use safety edges. In
the
device must sense people.
Loops cannot be used.
8
3
These are constant pressure inputs that
bypass the processor and may be used only
in an emergency if the processor fails.
Note left/right switch does not effect direction.
11
R1
R2
R3
11
TERMINAL STRIP
MASTER/SLAVE
ON SIDE OF
CONTROL PANEL
Use shielded twisted pair.
do not run with power wiring.
Figure 19
Controls and Accessory Installation
6
5
CLOSE/SINGLE BUTTON
CLOSE
5
EXTERNAL ENTRAPMENT CLOSE
Will reverse (open) the gate if active. If
any case,
entrapment is sensed during a reversal the
gate will stop. May defeat the timer to close.
E- OPEN
1
3
E- CLOSE
2
STOP BUTTON
- REQUIRED -
This is a normally closed input and the operator
will not run unless this is installed!
13
12
POWER
12
USE POWER TO MATCH GATE LOCK
REQUIREMENTS, NOT TO EXCEED
For warning devices,
call the factory
4
10
5
14
GATE LOCK
115V 10A.
01-G0665F19
Doc 01-G0665
Rev C
21