A total of 50 Security+ 2.0™ remote controls and 2 keyless entries (1 PIN for each keyless entry) can be programmed to the operator. When
programming a third keyless entry to the operator, the first keyless entry will be erased to allow the third keyless entry to be programmed. When the
operator's memory is full it will exit the programming mode and the remote control will not be programmed. The memory will need to be erased
before programming any additional remote controls. NOTE: If installing an 86LM to extend the range of the remote controls DO NOT straighten the
antenna.
There are 3 different options for programming the remote control depending on how you would like the remote control to function. Choose a
programming option:
OPTION
DESCRIPTION
Single button as OPEN
Program a single button on the
only
remote control for open only. The
Timer-to-Close can be set to close
the gate.
Single button (SBC) as
Program one remote control button
OPEN, CLOSE, and
as an open, close, and stop.
STOP
Three separate buttons
Program each remote control button
as OPEN, CLOSE, and
as an open, close, and stop.
STOP
The operator will automatically exit learn mode (operator will beep and green XMITTER LED will go out) if programming is successful. To program
additional Security+ 2.0™ remote controls or remote control buttons, repeat the programming steps above.
Once the remote control has been programmed the operator will operate as follows:
When gate is in the closed position, activation of the remote control button will open the gate. During the open cycle another activation of the remote
control will stop the gate and the next activation of the remote control will close the gate. When the gate is in the open position, activation of the
remote control button will close the gate. If the remote control is activated while the gate is closing, the gate will stop and the next activation will open
the gate.
NOTICE: This device complies with part 15 of the FCC rules and Industry Canada (IC) licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This Class B digital apparatus complies with Canadian ICES-003.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This manual downloaded from http://www.manualowl.com

PROGRAMMING

REMOTE CONTROLS (NOT PROVIDED)

PROGRAMMING STEPS
1. Press and release the LEARN button (operator will beep and green XMITTER
LED will light).
2. Press the OPEN button.
3. Press the remote control button that you would like to program.
1. Press and release the LEARN button (operator will beep and green XMITTER
LED will light).
2. Press the remote control button that you would like to program.
1. Press and release the LEARN button (operator will beep and green XMITTER
LED will light).
2. Press the OPEN, CLOSE, or STOP button, depending on the desired function.
3. Press the remote control button that you would like to program.