Programming; Switch #1: Operator Programming - Chamberlain LiftMaster Professional SW470 Installation And Maintenance Instructions Manual

Medium & heavy duty swing gate operators
Hide thumbs Also See for LiftMaster Professional SW470:
Table of Contents

Advertisement

Programming

Switch #1: Operator Programming

POLE #1 – SINGLE/CLOSE BUTTON
ON = Close button only
OFF = Open/Close Button
POLE #2 – RIGHT HAND/LEFT HAND
ON = Left Hand (gate will open to the left)
OFF = Right Hand (gate will open to the right)
(Determine hand selection from inside of fence looking out)
POLE #3 – WARNING DEVICE
ON = Warning device will turn on 3 seconds before gate starts
to move in either direction.
OFF = Warning device disabled.
Timer to close is locked out at the factory, to activate the timer to close, move timer disable jumper
from bottom two pins (show illustration) to top two pins. Then set time per the chart on page 20.
To lock the timer to close program and disable, simply return the jumper to the bottom two pins, or
move all pins of SW#2 to ON.
IMPORTANT NOTE: When using master/slave, only set the time for the master operator.
The slave operator must be set to disable position (all poles on).
POLE #4 – MASTER/SLAVE – SINGLE UNIT
ON = Master or single Unit
OFF = Slave unit
RED LED INFORMATION
Continuous ON = Unit is on a limit
Blinking 1 flash per second = Normal operation (gate travel or mid-stop)
Blinking 2 flashes per second = Entrapment level 1 (operator reverse to limit)
Figure 16
19
Programming
0 1 -G 06 6 5 F1 1
0 1-0 66 5 F1 2
Figure 17
Doc 01-G0665
Rev C