Accessory Wiring; External Control Devices - Chamberlain RSW12UL Installation Manual

Residential dc vehicular swing gate operator
Hide thumbs Also See for RSW12UL:
Table of Contents

Advertisement

All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P,
CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings.

External Control Devices

NOT TO BE USED AS ENTRAPMENT PROTECTION
EXIT (2 Terminals)
This input is a soft open command (maintained switch does not override
external safeties and does not reset alarm condition). Used for exit
probe, telephone entry, external exit loop detector, or any device that
would command the gate to open.
• Opens a closed or closing gate and holds open an open gate, if
maintained, pauses Timer-to-Close at OPEN limit.
SHADOW (2 Terminals)
This input is used for external shadow loop detector when loop is
positioned under the swing of the gate.
• Holds open gate at open limit
• Only active when the gate is at the OPEN limit, disregarded at all
other times
• Pauses Timer-to-Close at OPEN limit
INTERRUPT (2 Terminals)
This input is used for an external interrupt loop detector when loop is on
the outside of the gate.
• Holds open gate at open limit
• Stops and reverses a closing gate to open limit
• Pauses Timer-to-Close at OPEN limit, activates quick close and anti-
tailgate features when enabled on the expansion board

ACCESSORY WIRING

Access control device wiring
Loop wiring
29
Access Control Device
Exit
Com
Control board
Control board
Exit
Com
Shadow
Com
Interrupt
Com
Interrupt Loop
Shadow Loop
Exit Loop