v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, System x3105 Type 4347," on page 53 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
201-xxx-PBD
Test failed:
v B = Failing bank/pair number
v D = 9 = Both DIMMs in the failing
bank/pair of DIMMs
204-198-000
Test aborted.
204-210-000
Test failed.
215-xxx-000
Failed CD or DVD test.
217-xxx-000
Failed fixed disk test.
217-xxx-001
Failed fixed disk test.
44
IBM System x3105 Type 4347: Problem Determination and Service Guide
Action
v Reseat the failing DIMMs; then, run the memory
diagnostics test again.
v Replace the failing DIMMs; then, run the memory
diagnostic test again.
v (Trained service technician only) Replace the
system board.
1. Run the Quick Memory Test Diagnostic All Banks
(see "Running the diagnostic programs" on page
40).
2. Update the BIOS code (see "Updating the
firmware" on page 93).
3. Look in the test log (see "Viewing the test log" on
page 41) and correct any other errors.
1. Run the Quick Memory Test Diagnostic All Banks
(see "Running the diagnostic programs" on page
40).
2. Update the BIOS code (see "Updating the
firmware" on page 93).
3. Look in the test log (see "Viewing the test log" on
page 41) and correct any other errors.
1. Run the test again with a different CD or DVD.
2. Reseat the following components:
a. CD or DVD drive cable
b. Power switch/LED bracket cable
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. CD or DVD drive cable
b. CD or DVD drive
c. Power switch/LED bracket cable
1. Reseat hard disk drive 1 cable.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Hard disk drive 1 cable
b. Hard disk drive 1
1. Reseat hard disk drive 2 cable.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Hard disk drive 2 cable
b. Hard disk drive 2