IBM LS20 - BladeCenter - 8850 Service Manual page 62

For ibm bladecenter problem determination and service guide
Hide thumbs Also See for LS20 - BladeCenter - 8850:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8850," on page 53 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
201-xxx-PBD
Test failed.
v P = CPU Number [1 - 4].
v B = Failing Bank/Pair number.
v D = Failing dimm number within Failing
CPU # P.
v D = 9 = Both dimms in the failing
bank/pair of dimms.
202-xxx-001
Failed system cache test.
202-xxx-002
Failed system cache test.
217-198--xxx
Could not establish drive parameters.
217-xxx-000
Failed hard disk drive test.
Note: If RAID is configured, the fixed disk
number refers to the RAID logical drive.
217-xxx-001
Failed hard disk drive test.
Note: If RAID is configured, the fixed disk
number refers to the RAID logical drive.
405-xxx-000
Failed Ethernet test on controller on the
system board.
48
AMD Opteron LS20 Type 8850 for IBM BladeCenter: Problem Determination and Service Guide
Action
1. Reseat the failing DIMM, then; run the memory
diagnostic test.
2. Replace the failing DIMM(s), then; run the
memory diagnostic test.
3. (Trained service technician only) System board
assembly.
1. Reseat microprocessor 1.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. (Trained service technician only)
Microprocessor 1
b. (Trained service technician only) System
board assembly
1. Reseat microprocessor 2.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. (Trained service technician only)
Microprocessor 2
b. (Trained service technician only) System
board assembly
1. Reseat hard disk drive x.
2. Flash the BIOS code.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. Hard disk drive x
b. (Trained service technician only) System
board assembly
1. Reseat hard disk drive 1.
2. Replace hard disk drive 1.
1. Reseat hard disk drive 2.
2. Replace hard disk drive 2.
1. Make sure that Ethernet is not disabled in the
Configuration/Setup Utility program.
2. Update the Ethernet firmware (see "Configuring
the Gigabit Ethernet controllers" on page 88).
3. (Trained service technician only) Replace the
system board assembly.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amd opteron ls20 type 8850

Table of Contents