v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8850," on page 53 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
001-250-00n
ECC Test logic Failed. See PCDR logs. n =
failing CPU. [1 - 4]
001-292-000
Core system: failed/CMOS checksum failed. Load the BIOS default settings using the
001-xxx-000
Failed core tests.
001-xxx-001
Failed core tests.
005-xxx-000
Failed video test.
030-xxx-000
Failed internal SCSI interface test.
035-xxx-099
No adapters were found.
075-xxx-000
Failed power supply test.
089-xxx-001
Failed microprocessor test.
089-xxx-002
Failed optional microprocessor test.
46
AMD Opteron LS20 Type 8850 for IBM BladeCenter: Problem Determination and Service Guide
Action
1.
Restart the server.
2.
Run the diagnostic test again.
3. (Trained service technician only) If problem still
exists, replace the failing microprocessor.
Configuration/Setup Utility program and run the test
again (see "Configuration/Setup Utility menu choices"
on page 87).
(Trained service technician only) Replace the system
board assembly.
(Trained service technician only) Replace the system
board assembly.
(Trained service technician only) Replace the system
board assembly.
(Trained service technician only) Replace the system
board assembly.
Reseat the adapter (if installed).
Replace the power supply (refer to the Hardware
Maintenance Manual and Troubleshooting Guide or
Problem Determination and Service Guide for your
BladeCenter unit type).
1. Reseat microprocessor 1.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. (Trained service technician only)
Microprocessor 1
b. (Trained service technician only) System
board assembly
1. Reseat microprocessor 2.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. (Trained service technician only)
Microprocessor 2
b. (Trained service technician only) System
board assembly