e_hd250.book Page 106 Tuesday, October 24, 2006 3:11 PM
OTHERS

Warnings and Responses

Warnings are displayed on the LCD monitor or the viewfinder if there was a mistaken operation, if the battery or tape is low, or if
there is a problem on the VTR.
In addition, if the tape or battery is low or the VTR has a problem, the tally lamp flashes (or lights) and an alarm is output from the
monitor speaker or PHONES jack.
MEMO
GY-HD250/GY-HD251 uses microcomputers. It may not operate properly if there is external static or interference. If this hap-
pens, turn the power off and then on again.
Display
60/30 INHIBIT
The FRAME RATE item is set to 50/25 or 24, and a tape re-
CHANGE FRAME
corded in 60/30 frame is played back or it is input into the
RATE MENU
IEEE1394 port in VTR mode.
50/25 INHIBIT
The FRAME RATE item is set to 60/30 or 24, and a tape re-
CHANGE FRAME
corded in 50/25 frame or it is input into the IEEE1394 port
RATE MENU
in VTR mode.
24 INHIBIT CHANGE
The FRAME RATE item is set to 50/25 or 60/30, and a tape
FRAME RATE MENU
recorded in 24 frame is played back or it is input into the
IEEE1394 port in VTR mode.
AUX IN INHIBIT
• U model
CHANGE
Displays when the FRAME RATE item is set to 50/25 or
FRAME RATE MENU
24 and the GENLOCK/AUX IN switch is set to AUX IN.
• E model
Displays when the FRAME RATE item is set to 60/30 or
24 and the GENLOCK/AUX IN switch is set to AUX IN.
SYNC LOCKING
• Camera image is locking to external synchronization sig-
nals.
PLEASE WAIT
Displays when external synchronization signal is input and
REC trigger button is pressed while SYNC LOCKING is dis-
played.
INVALID SYNC
• Displays when the FRAME RATE item is set to 60/30 or
24 and signals not supported by GENLOCK are input.
• Displays when the FRAME RATE item is set to 50/25 and
signals not supported by GENLOCK are input.
DV-60I INVALID!
A tape recorded in DV-60I, DV-24P, or DV-24PA format
DV-24P INVALID!
was played back or input into the IEEE1394 connector in
DV-24PA INVALID!
VTR mode on the E model.
DV-50I INVALID!
A tape recorded in DV-50I or DV-25P format was played
DV-25P INVALID!
back or input into the IEEE1394 connector in VTR mode on
the U model.
HDV-SD60P
A tape recorded in HDV-SD60P format was played back or
INVALID!
input into IEEE1394 connector in VTR mode.
HDV-SD50P
A tape recorded in HDV-SD50P format was played back or
INVALID!
input into IEEE1394 connector in VTR mode.
INVALID TAPE!
A computer data tape or a DVC PRO cassette was used.
LP TAPE INVALID!*
Tried to play back a tape recorded in LP mode.
NO DV SIGNAL*
DV signal was not input.
NO HDV SIGNAL*
HDV signal was not input.
COPY INHIBIT*
Tried to record a copyguarded signal.
REC INHIBIT*
A tape that cannot be recorded (back switch is set to SAVE)
was inserted.
NO TAPE*
No videocassette tape is inserted.
106
Status
Sets the FRAME RATE item on the VIDEO FORMAT menu
screen to match the frames.
X See page 77.
Set the FRAME RATE item as shown below to input exter-
nal images.
U model : 60/30
E model : 50/25
It is not possible to enter recording mode while "SYNC
LOCKING" is displayed. Wait until the indication disap-
pears.
Input supported external synchronization signals.
X See page 66.
The E model cannot play back tapes recorded in DV-60I,
DV-24P or DV-24PA format or input into the IEEE1394 con-
nector in VTR mode.
The U model cannot play back tapes recorded in DV-50I or
DV-25P format or input into the IEEE1394 connector in
VTR mode.
GY-HD250/GY-HD251 cannot play back or input an HDV-
SD60P/HDV-SD50P signal.
Use a MiniDV videocassette.
GY-HD250/GY-HD251 cannot record or play back in LP
mode.
Set the IEEE1394 switch to DV and input a DV signal.
Set the IEEE1394 switch to HDV and input an HDV signal.
Cannot record a copyguarded signal.
Set the switch on the back of the cassette tape to REC.
Insert a cassette tape.
Action