Temp Indicator - Panasonic PTDZ8700U - DLP PROJECTOR Operating Instructions Manual

Dlp based projector
Hide thumbs Also See for PTDZ8700U - DLP PROJECTOR:
Table of Contents

Advertisement

Monitor Lamp indicators
J

TEMP indicator

Lamp
indication
Warm-up status
Lighting in red
High temperature
inside. (WARNING)
The filter is
Blinking in red
excessively dirty
(once)
and the ventilation
is poor.
High temperature
Blinking in red
inside.
(twice)
(Standby condition)
Blinking in red
Cooling fan has
(3 times)
been stopped.
Note
z
If no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.
J
FILTER indicator
Lamp
indication
The ACF unit has
Lighting in red
run out.
The ACF unit is not
Blinking in red
installed.
The ACF unit
remains few. The
Lighting in
remaining use time
orange
of the ACF unit is
approximately 200
hours.
Blinking in
The ACF unit cannot
orange
operate properly.
Note
z
If no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.
When the ACF unit is not installed, the filter indicator will blink in red and the power will turn off in 10 minutes.
z
When the FILTER indicator is flashing green, the Auto Cleaning Filter (ACF) is normally rolling up.
z
z
When the ACF unit is operating, operational sound may be heard.
z
The usable time after lighting of the orange lamp may be shortened in a dusty environment. The time of about 200 hours is
for reference only. Contact the dealer to purchase the new ACF unit earlier.
z
If the projector is used at elevations higher than 1 400 m above sea level with the [HIGH ALTITUDE MODE] at [OFF], the
lamp life or life of other components will be shortened.
z
Before the FILTER indicator blinks in orange when operational malfunction, mechanical sound of the clutch may be heard.
If the Smoke Cut Filter is installed, the green lamp, which takes longer to turn ON/OFF, will flash.
z
If the filter is running low, only one lamp lights even if [DUAL] is selected. The lamps will light as normal once the filter has
z
been replaced and the residual filter has been reset.
108
- ENGLISH
Information
z
Did you turn on the power when
the ambient temperature was
lower than approx. 0 °C (32 °F)?
z
Check the ventilation port is
blocked.
z
Is the room air temperature too
high?
Is the filter indicator lighted?
z
Information
z
Check the [REMAINING
FILTER] of [STATUS] in
[PROJECTOR SETUP] menu.
Æ
(
page 83)
z
Check the ACF unit
compartment.
z
Check the [REMAINING
FILTER] of [STATUS] in
[PROJECTOR SETUP] menu.
Æ
(
page 83)
z
Is foreign object blocking the
ACF unit operation?
Check point
z
z
z
z
z
z
Check point
z
z
z
z
z
Remedial measure
Wait about 5 minutes in the current
status.
Install the unit in a location having
an ambient temperature from 0 °C
(32 °F) - 45 °C (113 °F).
Remove the object that is blocking
the ventilation port.
Move the projector to a temperature
of 0 °C (32 °F) - 45 °C (113 °F) and
the humidity of 20 % to 80 % (no
condensation).
Turn off the MAIN POWER switch
using the procedure on page 40 and
replace the ACF unit.
Turn off the MAIN POWER switch
using the procedure on page 40 and
consult the dealer.
Remedial measure
Replace the ACF unit.
Replace the ACF unit.
Request the dealer to purchase the
new ACF unit.
Remove the foreign object from the
ACF unit.
When the foreign object still
remained, contact the dealer.