Temperature related system shutdown
Message
System shutoff due to CPU "X" over temperature
(level-critical; CPU "X" is over temperature)
System shutoff due to CPU "X" under temperature
(level-critical; CPU "X" is under temperature)
System shutoff due to DASD temperature (sensor X)
(level-critical; DASD area reported temperature outside
recommended operating range)
System shutoff due to high ambient temperature
(level-critical; high ambient temperature)
System shutoff due to faults on each supply
(level-critical; each installed power supply encountered a
fault condition)
DASD checkout
Message
Hard drive "X" removal detected
(level-critical; hard drive "X" has been removed)
Hard Drive (SCSI ID "X") fault
(level-critical; error has occurred on a DASD drive in a
RAID configuration causing it to be defunct)
CPU checkout
Message
Host BIST fail
(level-informational; host's built-in self test failed)
Internal Error CPU "X" fault
(level-critical; specified processor reported internal error and
is held offline and system restarted)
Action
1. Ensure system is being properly cooled, see
"Temperature checkout" on page 23
2. Replace CPU "X"
1. Ambient temperature must be within normal
operating specifications (see "Features and
specifications" on page 3
2.
1. Ensure system is being properly cooled, see
"Temperature checkout" on page 23
1. Ambient temperature must be within normal
operating specifications (see "Features and
specifications" on page 3
1. See "Power checkout" on page 20.
Action
1. Information only, take action as appropriate.
1. Ambient temperature must be within normal
operating specifications (see "Features and
specifications" on page 3
Action
1. Reseat CPU
2. Replace CPU
1. If problem persists, replace CPU "X".
121
Symptom-to-FRU index