IBM 8682 - Eserver xSeries 350 Hardware Maintenance Manual page 123

Hardware maintenance manual
Table of Contents

Advertisement

Error Code/Symptom
1301
(cable to front panel not found)
1302
(cable from system board to power on and
reset switches not found)
1303
(cable from system board to power
backplane not found)
1304
(cable to diagnostic LED board not found)
1600
(Advanced System Manage-ment
processor is not functioning) Do the
following before replacing a FRU:
1. Ensure that a jumper is not installed
on J5.
2. Remove the ac power to the system,
wait 20 seconds; then, re-connect the
ac power. Wait 30 seconds; then,
power-on the system.
1601
(The system is able to communicate to the
Service Processor, but the Service
Processor failed to respond at the start of
POST.)
Do the following before replacing a FRU:
1. Remove the ac power to the system,
wait 20 seconds; then, re-connect the
ac power. Wait 30 seconds; then,
power-on the system.
2. Flash update the Service Processor.
1800
(No more hardware interrupt available for
PCI adapter)
1962
(Drive does not contain a valid boot
sector)
FRU/Action
1. Cable
2. Front Panel
3. Power Switch Assembly
4. System Board
1. Cable
2. Power Switch Assembly
3. System Board
1. Cable
2. Power Backplane
3. System Board
1. Cable
2. Diagnostic LED Board
3. System Board
1. System Board
2. Service Processor Board
1. System Board
2. Service Processor Board
1. Run Configuration/Setup
2. Failing Adapter
3. System Board
1. Verify a bootable operating system is installed.
2. If RAID system, refer to the Hardware Maintenance Manual for the
specific RAID adapter.
3. Run Diagnostics
4. Hard Disk Drive
5. Cable
6. SCSI Backplane
7. System Board
113
Symptom-to-FRU index

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver xseries 350 type 8682

Table of Contents