Error Code/Symptom
020-XXX-002
(Failed Hot-Swap Slot 2 PCI Latch test)
020-XXX-003
(Failed Hot-Swap Slot 3 PCI Latch test)
020-XXX-004
(Failed Hot-Swap Slot 4 PCI Latch test)
020-XXX-005
(Failed Hot-Swap Slot 5 PCI Latch test)
020-XXX-006
(Failed Hot-Swap Slot 6 PCI Latch test)
030-XXX-000
(Failed Internal SCSI interface test)
030-XXX-00N
(Failed SCSI test on PCI slot N. Check
system error log before replacing a FRU.)
035-XXX-099
035-XXX-S99
(Failed RAID test on PCI slot S. S =
number of failing PCI slot. Check System
Error Log before replacing a FRU.)
035-XXX-SNN
(Check System Error Log before
replacing a FRU. S = number of failing
PCI slot; NN = SCSI ID of failing fixed
disk.)
035-253-S99
(RAID adapter initialization failure)
075-XXX-000
(Failed Power Supply test)
089-XXX-001
(Failed Microprocessor test)
089-XXX-002
(Failed Optional Microprocessor test)
089-XXX-003
(Failed Optional Microprocessor test)
104
IBM xSeries 350 Type 8682: Hardware Maintenance Manual
FRU/Action
1. PCI Hot-Swap Latch Assembly
2. System Board
1. PCI Hot-Swap Latch Assembly
2. System Board
1. PCI Hot-Swap Latch Assembly
2. System Board
1. PCI Hot-Swap Latch Assembly
2. System Board
1. PCI Hot-Swap Latch Assembly
2. System Board
1. System Board
1. Adapter in Slot N
1. No adapters were found.
2. If adapter is installed re-check connection.
1. Adapter
2. SCSI Backplane
3. Cable
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
1. ServeRAID Adapter in slot S is not configured properly. Obtain the
basic and extended configuration status and refer to the ServeRAID
Hardware Maintenance Manual for more information.
2. Cable
3. SCSI Backplane
4. Adapter
1. Power Supply
1. Microprocessor
1. Optional Microprocessor 2
1. Optional Microprocessor 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver xseries 350 type 8682

Table of Contents