Beep/Symptom
2-4-1
(Video failed, screen believed
operable)
3-1-1
(Timer tick interrupt failed)
3-1-2
(Interval timer channel 2 failed)
3-1-3
(RAM test failed above address
OFFFF h)
3-1-4
(Time-Of-Day clock failed)
3-2-1
(Serial port failed)
3-2-2
(Parallel port failed)
3-2-3
(Math coprocessor failed)
3-2-4
(Failure comparing CMOS memory
size against actual)
3-3-1
(Memory size mismatch occurred,
see "Memory Settings" on page 37)
3-3-2
(Critical SMBUS error occurred) (I2C
bus error)
3-3-3
(No operational memory in system)
FRU/Action
1. System board
1. System Board
1. System Board
1. DIMM
2. Memory card
3. System board
1. Battery
2. System Board
1. System board
1. System board
1. Optional processor (if installed)
2. Processor
3. System board
1. DIMM
2. Battery
3. System board
1. DIMM
2. System board
3. Battery
1. Disconnect the server power cord from outlet, wait 30 seconds and
retry.
2. System Board
3. DIMMs
4. Memory Card
5. DASD Backplane
6. Power Supply
7. Power Supply Backplane
8. 12C Cable
1. Install or reseat the memory modules, then do a 3 boot reset. (See
"Using the Configuration/Setup Utility program" on page 33)
2. DIMMs
3. Memory Card
4. System Board
99