Error Code/Symptom
00180300
(No more memory (above 1MB for PCI
adapter)
00180400
(No more memory (below 1MB for PCI
adapter)
00180500
(PCI option ROM checksum error)
00180600
(PCI device built-in self test failure)
00180700
(xxxxyyyy planar PCI device not
responding (where xxxx is PCI vendor ID
and yyyy is PCI device ID)
00180800
(Unsupported PCI device installed)
00181000
(PCI error)
01295085
(ECC checking hardware test error)
01298001
(No update data for processor 1)
01298002
(No update data for processor 2)
01298003
(No update data for processor 3)
01298004
(No update data for processor 4)
01298101
(Bad update data for processor 1)
01298102
(Bad update data for processor 2)
01298103
(Bad update data for processor 3)
FRU/Action
1. Run Configuration/Setup
2. Failing Adapter
3. System Board
1. Run Configuration/Setup
2. Failing Adapter
3. System Board
1. Remove Failing PCI Card
2. System Board
1. Run Configuration/Setup
2. Failing Adapter
3. System Board
1. System Board
2. PCI Card
1. System Board
2. PCI Card
1. System Board
2. PCI Card
1. System Board
2. Processor
1. Ensure all processors are the same stepping level and cache
size.
2. Processor 1
1. Ensure all processors are the same stepping level and cache
size.
2. Processor 2
1. Ensure all processors are the same stepping level and cache
size.
2. Processor 3
1. Ensure all processors are the same stepping level and cache
size.
2. Processor 4
1. Ensure all processors are the same stepping level and cache
size.
2. Processor 1
1. Ensure all processors are the same stepping level and cache
size.
2. Processor 2
1. Ensure all processors are the same stepping level and cache
size.
2. Processor 3
115