System Shutdown; Voltage Related System Shutdown - IBM 8682 - Eserver xSeries 350 Hardware Maintenance Manual

Hardware maintenance manual
Table of Contents

Advertisement

Message
Power Supply "X" fault
(level-critical; power supply "X" has been removed or has
encountered some other fault)
Power Supply "X" overvoltage fault
(level-critical)
Power Supply "X" AC power removed, early power-off
warning
(level-critical; a power supply has been unplugged or has
been installed without an ac cord)
System running non-redundant power
(level-non-critical; system does not have redundant power)
System under recommended voltage for "X" v
(level-warning; indicated voltage supply under nominal
value; value for "X" can be +12, -12, or +5)
System under recommended voltage on 3.3 v
(level-warning; 3.3 volt supply under nominal value)
"X" V bus fault
(level-critical; overcurrent condition on "X" voltage bus)
12V "X" bus fault
(level-critical; overcurrent condition on 12 volt "X" voltage
bus)
5V fault
(level-critical; overcurrent condition on 5 V subsystem)

System shutdown

Refer to the following tables when experiencing system shutdown related to voltage
or temperature problems.

Voltage related system shutdown

Message
System shutoff due to "X" V over voltage
(level-critical; system shutoff due to "X" supply over
voltage)
System shutoff due to "X" V under voltage
(level-critical system shutoff due to "X" supply under
voltage)
120
IBM xSeries 350 Type 8682: Hardware Maintenance Manual
Action
1. Check error log for other messages.
2. See "Power checkout" on page 20
1. See "Power checkout" on page 20.
1. Check to see if ac cords are plugged in properly.
2. Problem may have been temporary ac problem. If
problem persists, see "Power checkout" on page 20
1. Add another power supply
2. Remove options from system
3. System can continue to operate without redundancy
protection if 1 and 2 above are not followed.
1. Check connections to power subsystem
2. Replace power supply
3. Replace power backplane
1. Check connections to power subsystem
2. Replace power supply
3. Replace power backplane
1. See "Power checkout" on page 20.
1. See "Power checkout" on page 20.
1. See "Power checkout" on page 20.
Action
1. Check power supply connectors
2. Replace power supply
3. Replace power backplane
1. Check power supply connectors
2. Replace power supply
3. Replace power backplane

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eserver xseries 350 type 8682

Table of Contents