Parallel SCSI configuration

This menu allows for setting up SCSI attributes.
Figure 42
Parallel SCSI configuration menu
X.XX.XX
Current SCSI Configuration - Bus 0
Discovery
Bus Reset on Boot
Discovery delay time
Internal Termination
1) Edit Initiator Settings
2) Enable/Disable SCSI Discovery
3) Enable/Disable SCSI Reset on Boot
4) Set Discovery Delay Time
5) Set SCSI Termination Mode
6) Set Maximum SCSI Bus Connect Speed
X) Return to previous menu
Command, <enter> for next bus >
Press the Enter key to toggle the current menu to the next SCSI bus.
Select 1 to edit the SCSI Initiator menu settings, described later in the chapter.
Select 2 to enable/disable SCSI Discovery.
Select 3 to enable/disable SCSI bus Reset on Boot. When enabled, the network storage router
automatically resets SCSI buses after initial library power-up and after reboots.
Select 4 to set the discovery delay time for SCSI devices. The default is 30 seconds. This is the time the
network storage router waits after a power-up or reboot before starting to discover SCSI devices. This
value should be set to no less than 250ms, according to the SCSI standard for Reset-to-Selection Time.
This value may need to be increased to ensure that all SCSI devices complete their individual
power-ups. With Discovery enabled, the Discovery Delay lengthens the time taken by the network
storage router to reboot.
Select 5 to toggle the SCSI termination mode between Enabled and Disabled. This option is
automatically set to Enabled for Internal termination. The Internal setting allows the network storage
router to internally terminate a SCSI connection. Setting this option to Disabled allows the SCSI bus, not
the network storage router, to handle SCSI terminations.
Select 6 to access menu settings for the maximum SCSI bus connection speed, described later in this
chapter. Note that when this option is selected, the user is prompted to select a Target ID on the
currently selected bus. Currently, maximum speed settings are shown.
Parallel SCSI Configuration Menu
XXXXXX
XXXXXXXXXXXXXXXX
07/7/2005
08:56:22
: Enabled
: Enabled
: 30 seconds
: Enabled
N1200-320 4Gb Network Storage Router user and service guide