Fibre Channel port configuration
When the Fibre Channel port is selected in Ports menu, the Fibre Channel Configuration screen is
displayed (see
Figure 22
Fibre Channel port 0 configuration settings screen
Fibre Channel port settings:
•
Link Status indicates the port link status.
•
Port Mode (default: N_Port) sets the port mode.
Port Mode settings:
• Auto Sense: In this mode, the Fibre Channel port tries to negotiate as a loop. If it is not successful,
then the Fibre Channel port negotiates as a fabric. If the port comes up as a loop, it then determines
whether it is on a private or public loop.
• N_Port: (default) This mode allows the network storage router to bypass the loop negotiation and
come up as a fabric only. If the network storage router is on a loop, and N_Port mode is selected,
an error in communication may occur.
•
Use Hard AL_PA enables or disables Hard AL_PA usage.
•
Hard AL_PA Settings displays the AL_PA Lookup Table.
Use the table to find the node number. This unique one-byte valid value (derived from an Arbitrated
Loop Topology defined in ANSI specification FC_AL version 4.5) is used for the Fibre Channel
configuration.
•
Discovery Mode (default: Manual Discovery Only) determines how the network storage router discovers
new Fibre Channel devices.
Discovery mode settings:
• Auto Discovery on Reboot allows the network storage router to automatically discover all Fibre
Channel devices when rebooted or when link-up events occur, such as connecting cables or
rebooting network hubs.
• Both the ports and the devices behind the ports are discovered on all subsequent link-up events.
42
Visual manager user interface
Figure
22).
Need help?
Do you have a question about the N1200 - StorageWorks Network Storage Router and is the answer not in the manual?