6.17.4 Disengaging the needle bar with subclass 888-460522

34
The needle bars are switched on and off with the "L" and "R" keys.
Press the "L" key.
The key is illuminated.
The left needle bar is switched off.
Sewing.
Press the "L" key once more.
The key is no longer illuminated.
The left needle bar is switched on again.
Press the "R" key.
The key is illuminated.
The right needle bar is switched off.
Sewing.
Press the "R" key once more.
The key is no longer illuminated.
The right needle bar is switched on again.
Note:
It is not possible to switch off both needle bars at the same time. In
order to switch on the second needle bar again both keys, "L" as well
as "R" may be pressed.