Adjusting The Needle Bar And The Hook; Needle Bar Height, Play Of Needle To Hook Tip, Loop Stroke - DURKOPP ADLER 887 Service Instructions Manual

Hide thumbs Also See for 887:
Table of Contents

Advertisement

4

Adjusting the needle bar and the hook

4.1

Needle bar height, play of needle to hook tip, loop stroke

Rule:
When the handwheel pointer indicates "205" degrees (2.3 mm loop
stroke), the hook tip should stand at the needle axis at the stitch
length "0". Length (A) = 1.5 mm, distance (B) = 0.02 to 0.1 mm.
1
4
5
3
6
5
Lock the handwheel in loop stroke position (2.3 mm) by using the
locking pin (1) 5 mm, degree "205".
Loosen four screws (2) and turn the hook tip (3) to the needle axis.
Loosen screw (4), position the needle bar and needle to the
distance measure (A) and tighten screw (4).
Loosen the two screws (5) and displace the hook case (6) to the
distance measure (B).
Check whether the hook tip (3) is positioned in the range of the
needle axis, tighten screws (2).
25
2
EN
B