PDG-DWL100 Expand Serial Command Functional Specifications
8.7 Screen Control Command
8.7.1
CF_SCREEN Command
Command
"CF_SCREEN_%1" [CR]
"NORMAL" ----------- Select 4:3 screen display
"WIDE" ---------------- Select 16ÿ 10 screen display
%1
"TRUE" ---------------- Select native screen display
"UP" -------------------- Switch screen upward
"DN" -------------------- Switch screen downward
Select screen size. (Valid only when in the normal Power ON status.)
Details
The projector shows Image OSD at receiving the command.
Acceptable
Correspondence
Unacceptable
8.7.2
CF_KEYSTONE Command
Command
"CF_KEYSTONE _%1" [CR]
"UP" ------------------ Correct Keystone distortion to resize upper part of image
"FUP" ---------------- Correct Keystone distortion to resize upper part largely
%1
"DN" ------------------ Correct Keystone distortion to resize lower part of image
"FDN" ---------------- Correct Keystone distortion to resize lower part largely
"RST" ---------------- Reset keystone adjust
Change the correction level of Keystone distortion.
(Valid only when in the normal Power ON status.)
When the value reaches the correction limit, the projector accepts the
Details
command but does not execute it.
The behavior is the same as the "Keystone +/-" button of the remote control
A scale OSD is shown by adjusting Keystone and the scale reflects adjusting
value
Acceptable
Correspondence
Unacceptable
8.7.3
CF_MOUNTING Command
Command
"CF_MOUNTING_%1" [CR]
"FDESKTOP" ------------------ Select Front-Desktop
"RDESKTOP" ------------------ Select Rear-Desktop
%1
"FCEILING" --------------------- Select Front-Ceiling
"RCEILING" -------------------- Select Rear-Ceiling
Details
Select Mounting mode. (Valid only when in the normal Power ON status.)
Acceptable
Correspondence
Unacceptable
8.7.4
CF_DZCENT Command
Command
"CF_DZCENT_%1" [CR]
%1
"CENT" ------------------ Cancel Digital Zoomÿ CENTÿ "CENTERÿ
Cancel Digital Zoom
Details
When image is expanded or shrunk, reset its value.
(Valid only when in the normal Power ON status.)
Acceptable
Correspondence
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
22 / 47