Cr_Tempwarn Command; Cr_Tempfail Command - Sanyo PDG-DWL100 - WXGA DLP Projector Command Manual

Rs232c expand
Hide thumbs Also See for PDG-DWL100 - WXGA DLP Projector:
Table of Contents

Advertisement

PDG-DWL100 Expand Serial Command Functional Specifications

9.12.5 CR_TEMPWARN Command

Command
"CR_TEMPWARN" [CR]
Get the information about the temperature inside the projector
(1) close to an abnormal status 2) in an abnormal status 3) temperature
Details
level is normal 4)abnormal status is not detected).
Possible to get data from plural sensor s at once.
Acceptable
Correspondence
Unacceptable

9.12.6 CR_TEMPFAIL Command

Command
"CR_TEMPFAIL" [CR]
Get the temperature inside the projector when the abnormal status occurs.
Details
Possible to get the data from plural sensors at once.
Acceptable
Correspondence
Unacceptable
"000_%1" [CR]
"*_*"
Sensor 1 data comes first, and then one space, after that
sensor 2 data is followed.
Each data is as below:
"W"--- in or close to the abnormal temp. (Warning Temp.)
%1
"S"--- in the safe level of temperature (Safe Temp.).
"N"--- the given sensor does not detect abnormal temp.
e.g. "S_W" [CR] indicates that the temperature detected at
Sensor 1 is in the safe level while Sensor 2 in the abnormal
temperature.
"?" [CR]
"000_%1" [CR]
e.g. "_31.5F"[CR]
_ indicates a space.
When the temperature goes under 0, the first character
become "-", such as "-05.5F".
With more than one temperature sensors installed, projector
returns the data of each sensor in order.
e.g. "_31.5F_35.2S" [CR]
The first data indicates sensor 1, then sensor 2 data follows
after single space.
Last character in each data indicates the status of
temperature;
In the abnormal temperature --------------------- "F"
%1
In the safe level of temperature ------------------- "S"
Neither in or close to the abnormal temp. ------- "N"
The second example above indicates that the temperature
detected by sensor 1 is 31.5 and temperature is abnormal,
and at sensor 2 is 32.5 degrees and temperature is in the
safe temperature.
When the abnormal temperature status is not occurred the
data become "_00.0S".
When the projector is reset, "_00.0S" is set.
Every time abnormal temperature status is detected, it
renews the data and returns it. It only returns the renewed
data of the latest abnormal temperature and the previous
data is cleared.
"?" [CR]
46 / 47

Advertisement

Table of Contents
loading

Table of Contents