Site Environment; Preventive Site Configuration; Power Supply Considerations - Cisco 5580-40 - ASA Firewall Edition Hardware Installation Manual

Adaptive security appliance
Table of Contents

Advertisement

Chapter 2
Safety and Site Requirements

Site Environment

Place the chassis on a desktop or mount it on a rack. The location of the chassis and the layout of the
equipment rack or wiring room are extremely important for proper system operation. Equipment placed
too close together, inadequate ventilation, and inaccessible panels can cause system malfunctions and
shutdowns, and can make the chassis maintenance difficult.
When planning the site layout and equipment locations, keep in mind the precautions described in the
next section
possibility of environmentally caused shutdowns. If you are currently experiencing shutdowns or
unusually high error rates with your existing equipment, these precautions may help you isolate the
cause of failures and prevent future problems.

Preventive Site Configuration

The following precautions will help plan an acceptable operating environment for the chassis and avoid
environmentally caused equipment failures:

Power Supply Considerations

For information on power supply considerations including environmental operating ranges and power
requirements, see table 8 at the following url:
http://www.cisco.com/en/US/prod/collateral/vpndevc/ps6032/ps6094/ps6120/product_data_sheet0900a
ecd802930c5.html
The ASA can have an AC power supply.
Observe the following considerations:
OL-12920-01
Configuring Equipment Racks, page 2-4
"Preventive Site Configuration, page
Electrical equipment generates heat. Ambient air temperature might not be adequate to cool
equipment to acceptable operating temperatures without adequate circulation. Ensure that the room
in which you operate your system has adequate air circulation.
Always follow the ESD-prevention procedures described previously to avoid damage to equipment.
Damage from static discharge can cause immediate or intermittent equipment failure.
Ensure that the chassis top panel is secure. The chassis is designed to allow cooling air to flow
effectively within it. An open chassis allows air leaks, which may interrupt and redirect the flow of
cooling air from the internal components.
Check the power at the site before installing the chassis to ensure that the power is "clean" (free of
spikes and noise). Install a power conditioner if necessary, to ensure proper voltages and power
levels in the source voltage.
Install proper grounding for the site to avoid damage from lightning and power surges.
In a chassis equipped with an AC-input power supply, use the following guidelines:
The chassis does not have a user-selectable operating range. Refer to the label on the chassis for
the correct AC-input power requirement.
Several styles of AC-input power supply cords are available; make sure you have the correct
style for your site.
Cisco ASA 5580 Series Adaptive Security Appliance Hardware Installation Guide
2-3," to help avoid equipment failures and reduce the
General Site Requirements
2-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asa 5580

Table of Contents