Table 1-5
Rated input power
Rated input current
Maximum heat dissipation
Power supply output
Environment
Temperature
Maximum wet bulb temperature
Relative humidity
(noncondensing)
Altitude
Shock
Vibration
1. With full card installation and two power supplies.
2. At sea level with an altitude derating of 1.8
10,000 ft (3050 m). no direct sustained sunlight.
In a failover configuration, the two units must have the same hardware configuration. They must be the
same model, have the same number and types of interfaces, and the same amount of DRAM.
The two units do not have to have the same size flash memory. If using units with different flash memory
Note
sizes in your failover configuration, make sure the unit with the smaller flash memory has enough space
to accommodate the software image files and the configuration files. If it does not, configuration
synchronization from the unit with the larger flash memory to the unit with the smaller flash memory
will fail.
Cisco ASA 5580 Series Adaptive Security Appliance Hardware Installation Guide
1-14
ASA 5580 Specifications (continued)
1161W @ 100 VAC
1598W @ 200 VAC
12A (100 VAC)
8A (200 VAC)
3960 BTU/hr (100 VAC)
5450 BTU/hr (200 VAC)
910 W (low line)
1300 W (high line)
Operating 50 to 95°F (10 to 35°C)
Nonoperating -40°F to 158°F (-40°C to 70°C)
82.4°F (28°C)
Operating 10% to 90%
Nonoperating 5% to 95%
Operating 0 to 6500 ft (2000 m)
Nonoperating 0 to 30,000 ft (9144 m)
Operating Half-sine 2 G, 11 ms pulse, 100 pulses
Nonoperating 25 G, 170 inches/sec delta V
2.2 Grms, 10 minutes per axis on all three axes
°
F per every 1000 ft (1.0
Chapter 1
Introduction to the ASA 5580
2
°
C per every 3.0m) above sea level to a maximum of
OL-12920-01