Patch Cables; Rj-45 Plug And Rj-45 Connectors - NETGEAR GS108T - ProSafe - Gigabit Smart Switch Software Administration Manual

Smart switch
Hide thumbs Also See for GS108T - ProSafe - Gigabit Smart Switch:
Table of Contents

Advertisement

GS108T Smart Switch Software Administration Manual
located. NEXT measures the amount of energy that is "returned" to the sender end. The factors
that affect NEXT and cross talk are exactly the same as outlined in the
cross-talk performance is directly related to the quality of the cable installation.

Patch Cables

When installing your equipment, replace old patch panel cables that do not meet Category 5e
specifications. As pointed out in the
critical for successful operation.

RJ-45 Plug and RJ-45 Connectors

In a Fast Ethernet network, it is important that all 100BASE-T certified Category 5 cabling use
RJ-45 plugs. The RJ-45 plug accepts 4-pair UTP or shielded twisted-pair (STP) 100-ohm cable
and connects into the RJ-45 connector. The RJ-45 connector is used to connect stations, hubs, and
switches through UTP cable; it supports 10 Mbps, 100 Mbps, or 1000 Mbps data transmission.
Figure C-4
shows an RJ-45 plug and RJ-45 connector with built-in LEDs.
Figure C-4
Table C-2
lists the pin assignments for the 10/100 Mbps RJ-45 plug and the RJ-45 connector.
Table C-2. 10/100 Mbps RJ-45 Plug and RJ-45 Connector Pin Assignments
Pin
Normal Assignment on Ports 1 to 8
1
Input receive data +
2
Input receive data –
3
Output transmit data +
C-6
"Near End Cross
Talk" section, this near end piece of cable is
Uplink Assignment on Port 8
Output transmit data +
Output transmit data –
Input receive data +
v1.0, December 2007
"Return
Loss" section. The
Network Cabling

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents