Troubleshooting
operation, which may cause your KME61 to send MIDI Controller messages constantly.
The taper of the control should be linear for easy, predictable control. Pedals designed for
volume control will typically have most of their range concentrated in the upper half of travel.
To check taper, run the Control Pedal diagnostic and check the reading when the pedal is
pressed halfway down. If it's less than about 50, then it has an audio taper and will probably
be difficult to use.
Pedals may have a control range that is less than 0-127. To check this, run the Control Pedal
diagnostic and check the reading at both extremes of pedal motion. Good is a minimum
reading of 0 or 1 and a maximum of 126 or 127. If one end is OK but doesn't quite reach at the
other end, it may be possible to adjust the linkage or gear to properly center its range.

If None of the Above...

If your problem is not covered above, or none of the suggestions seems to work, first check
back and review the relevant sections of this manual. Many difficulties are just programming
problems caused by inappropriate settings of setup parameters. If you want to be sure that all
of the factory defaults are in place, refer to Hard System Reset in Chapter 6 Master Mode.
Also be sure to check out Kurzweil's Internet web site for additional KME61 information that
may have been published since this manual was written:
www.kurzweilmusicsystems.com

Service Centers

Contact the nearest Young Chang office listed at the front of this book to locate your local
Young Chang/Kurzweil representative.

Diagnostics

The KME61 has extensive diagnostic software built-in that can be used to test for proper
operation of almost every component. Although this chapter is intended primarily for service
personnel, the diagnostic software can also be helpful for identifying problems with the
cables and external controls.

Starting Diagnostics

1. Turn the power switch off.
2. Press and hold the two buttons marked "+" and "-" on the front panel.
3. Turn the power switch on while continuing to hold the buttons.
4. Wait until the soft button LEDs begin to flash then release the buttons.
5. On the LCD, "System Diag Wait" will be displayed briefly then the Main Diagnostic
Menu will become active:
SYSTEM DIAG READY
SCAN
7-4
LCD
ENGINE