TJERNLUND SS1C SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504103 REV 0702 Installation Instructions Manual

Includes new uc1 universal control

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS

Recognize this symbol as an indication of important Safety Information!
!
OWNER INSTRUCTIONS, DO NOT DESTROY
NOTE: FLUE GAS TEMPERATURES MUST NOT EXCEED
301 o C (575 o F) AT VENT SYSTEM INLET.
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED
SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND
OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY
BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW
THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUST-
MENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRI-
CAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, OR PERSONAL
INJURY OR PROPERTY DAMAGE.
DO NOT DESTROY. PLEASE READ CAREFULLY AND
KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
Copyright © 2002, Tjernlund Products, Inc. All rights reserved
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
MODEL SS1C
INCLUDES NEW UC1
UNIVERSAL CONTROL
REV. 8/02
P/N 8504103

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SS1C SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504103 REV 0702 and is the answer not in the manual?

Questions and answers

Summary of Contents for TJERNLUND SS1C SIDESHOT WITH UC1 UNIVERSAL CONTROL (VERSION X.02) 8504103 REV 0702

  • Page 1: Installation Instructions

    MENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRI- CAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, OR PERSONAL INJURY OR PROPERTY DAMAGE. DO NOT DESTROY. PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. Copyright © 2002, Tjernlund Products, Inc. All rights reserved P/N 8504103...
  • Page 2: Table Of Contents

    Tjernlund Products welcomes your comments and questions. Address all correspondence to: Customer Service • Tjernlund Products, Inc. • 1601 Ninth Street • White Bear Lake, MN 55110-6794 Call us toll free at 800-255-4208, visit our web site @ www.tjernlund.com or email us at fanmail@tjfans.com. TABLE OF CONTENTS Page (s) Description and Specifications ............................1, 2...
  • Page 3: Installation Restrictions

    SPECIFICATIONS Motor: 115/1/60, 3300 RPM, 212 watts, 2.28 FLA Fan Proving Switch: Non-adjustable, N/O with a set point of -.04" W.C. High Limit: Manual reset, N/C contacts, open at 79 o C (175 o F) + 8 o C (15 o F) UC1 Universal Control: See UC1 Universal Control Board Features on page 4.
  • Page 4: Safety Inspection Of A Previously Used Appliance

    The SS1C must be installed by a qualified installer (an individual properly licensed and/or trained) in accordance with all local codes or, in their absence, in accordance with “The National Building Code of Canada” CSA Std B139 & “The Canadian Electrical Code”...
  • Page 5: Sideshot ® With Integral Uc1 Universal Control Board Features

    P1 - P2 SAFETY CIRCUIT C, GND, F AUXILIARY DEVICE TERMINALS COMMUNICATION TERMINALS 1 mA @ 5VDC. 2 mA @ 5VDC. For Tjernlund MAC1E or SEE WARNING # 1. MAC4E auxiliary devices. SEE WARNING # 1. DIP SWITCH SETTINGS Pre-Purge (1-2)
  • Page 6: Pre / Post-Purge & Prover Status Check Settings

    PRE / POST PURGE AND PROVER STATUS CHECK DIP SWITCH SETTINGS Remove power to SS1C and heating equipment when installing, servicing or changing dip switch settings. Failure to do so may result in personal injury and/or equipment damage. LED #5 (RED) should not be on if 115 VAC supply power is removed from the control. Pre-purge Used for a Venter with longer vent runs to get draft fully established throughout the vent system prior to burner ignition.
  • Page 7: Termination Clearances

    PLENUM AND VENT HOOD CLEARANCE FROM COMBUSTIBLES With an inlet flue gas temperature of 301 o C (575 o F) or below, the SideShot has been Listed for the following clearances from combustible materials: IMPORTANT Vent Hood and top of Plenum: Zero Clearance Plenum front and sides: 1.3cm (1/2 inch) Plenum rear: 7.6cm (3 inches) VENT HOOD TERMINATION CLEARANCES...
  • Page 8: Installation

    INSTALLATION Tools required: • Reciprocating Saw • 1/2", 7/16",5/8" Wrench • Drill and 1/8", 1/4", 1/2" Bits • 1/4" Masonry Drill Bit • Blade Screwdriver • 1/4", 5/16”, 11/32" Nut Runner or Socket • Wire Cutter/Stripper • Hammer • Tube Cutter INSTALLING VENT HOOD TERMINUS 1.
  • Page 9: Vent Hood Installation

    DIAGRAM D DIAGRAM E NOTE: For mounting on vinyl or lap siding a wood frame with 1” x 1 1/2” on the sides and top and 1” x 2” material on bottom can be utilized on exterior wall. This will provide a flush mounting surface for the hood and a nicely finished look with “J”...
  • Page 10: Plenum Installation

    NOTCH BRACING It is recommended and local codes may dictate that the joist be reinforced as outlined below. Bracing of the rim joist is not necessary. 1. Cut two 2 x 4 pieces of wood 71 cm (28 inches) in length. 2.
  • Page 11: Installation Of Vent Pipe

    DIAGRAM J IMPORTANT: Adjust SS1C mounting bracket for a slight downward pitch towards exit terminal. INSTALLATION OF VENT PIPE A barometric draft control must be used. Install the barometric draft control as shown, (See Diagram K). The SideShot Vent System is designed to accept all brands of 6" single wall, Class "A" or Type "L" vent pipe. Type “B” is not suitable for the SS1C. The vent pipe used must be in compliance with local codes and the listing of the vent pipe manufacturer.
  • Page 12 4. Using a tube cutter, cut the sensing tube 2" from the elbow directed at the vent pipe inlet collar, (See Diagram L). Discard the cut off section of metal tube. 5. Attach the vent pipe inlet collar to the rear inlet port making sure that the sensing tube is orientated as shown, (See Diagram M). NOTE: Alignment marks on the inlet collar and plenum casing must match.
  • Page 13: Electrical Wiring

    The steps listed under each diagram are intended as a supplement to the diagram. Wiring colors or designations may vary by manufacturer. If you are unable to wire the SS1C as outlined in these instructions, call Tjernlund’s Customer Service Department toll free at 1-800-255-4208 for assistance.
  • Page 14 SIDESHOT WITH INTEGRAL UC1 UNIVERSAL CONTROL CONNECTED TO A HONEYWELL R8184 SERIES OR EQUIVALENT PRIMARY CONTROL IMPORTANT: RED JUMPER POSITION MUST BE THE SAME BLACK AS APPLIANCE INTERLOCK VOLTAGE. ORANGE WHITE IGNITION TRANS CALL JUMPER HONEYWELL WHITE R8184 SERIES OR EQUIVALENT WHITE BLACK SUPPLY...
  • Page 15: Wiring To Oil Fired Equipment

    SIDESHOT WITH INTEGRAL UC1 UNIVERSAL CONTROL CONNECTED WITH AN AQUASTAT IMPORTANT: LEGEND: RED JUMPER POSITION MUST BE THE SAME 115 VAC AS APPLIANCE INTERLOCK VOLTAGE. AQUASTAT D/N 9183046-7 CALL JUMPER SUPPLY LINE VOLTAGE OIL BURNER 115 VAC PRIMARY CONTROL, BURNER 50/60 Hz RELAY OR GAS VALVE GROUND...
  • Page 16 SIDESHOT WITH INTEGRAL UC1 UNIVERSAL CONTROL CONNECTED WITH A SINGLE ZONE 24 VAC THERMOSTAT IMPORTANT: RED JUMPER POSITION MUST BE THE SAME AS APPLIANCE INTERLOCK VOLTAGE. THERMOSTAT CALL JUMPER SUPPLY INTERNAL CONTROL LEGEND: 115 VAC OF FURNACE 50/60 Hz 115 VAC GROUND 24 VAC IMPORTANT:...
  • Page 17: Fan Proving Switch Bleed Orifice Selection

    SELECTION OF PRESSURE SWITCH BLEED ORIFICE In order for the SideShot pressure switch to function properly for the intended application, the proper bleed orifice has to be selected as determined below. 1. Upon installation, if the vent connector length is less than 3.1 equivalent meters (10 feet), then the smaller opening #52 bleed orifice should be used.
  • Page 18: Combustion Air

    Do not allow heating system to run at less than a -.02” W.C. over fire draft or at a CO level that is less than a 1% reduction from the value measured at a trace of smoke and a -.02” W.C. over fire draft. If these parameters are unobtainable, contact Tjernlund at 1-800-255-4208 for Technical Assistance.
  • Page 19: System Operation Check Out

    Accessory air intakes are available that connect to the burner motor, using it to pull in the outdoor air. The Tjernlund IN-FORCER Combustion Air Intake tempers the raw outdoor air as it is delivered to the burner.
  • Page 20: Troubleshooting Electrical Problems

    Extreme caution must be exercised to prevent injury. If you are unable to determine the defective part with the use of this guide, call your Tjernlund distributor or Tjernlund Products direct at 1-800-255-4208 for further assistance. IMPORTANT: To reset faults, verify fault by checking the LEDs and then remove call for heat.
  • Page 21: Maintenance

    SYMPTOM 3: SS1C OPERATES, BUT BURNER DOES NOT NOTE: Prover status check must be activated, see page 5. For any newly established call for heat the SS1C will run for 60 sec- onds to try to close the fan prover circuit (P1 to P2). If circuit can not be made after 60 seconds LED's 4 & 5 (Red) will flash in uni- son, indicating a prover check circuit fault on SS1C start up.
  • Page 22: Warranty & Replacement Parts

    Tjernlund Products, Inc. will issue credit or provide a free part to replace one that becomes defective during the two year warranty period. Proof of date of the installation in the form of the contractor sales/installation receipt is necessary to prove the unit has been in service for under two years.
  • Page 23 TJERNLUND LIMITED TWO YEAR WARRANTY Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (2) years from the date of original purchase or delivery to the original purchaser, whichever is earlier.
  • Page 24: Installer Notes

    INSTALLER NOTES...
  • Page 26: Template A Vent Hood Terminus

    BACKSIDE OF TEMPLATE B...