TJERNLUND 950-0020 115V COOLING FAN 8504073 REV. A 0906 Manual

TJERNLUND 950-0020 115V COOLING FAN 8504073 REV. A 0906 Manual

115 vac fan

Advertisement

FOR SS2 SIDESHOT® VENT SYSTEMS SEE INSTRUCTIONS BELOW
Disconnect power supply before servicing SS2 to prevent electrical shock and equipment damage.
1. Disconnect flue pipe from inlet collar of SS2.
2. Remove SS2 inlet pipe by twisting counterclockwise, (See Diagram A).
3. Remove (9) screws from rear and bottom of vent cabinet. Slide venter assembly out of vent cabinet and lay on its side on a flat
working surface, (See Diagram B).
4. Remove the BLACK and WHITE wires connected to the cooling fan.
5. Remove the (4) nuts holding the cooling fan guard and cooling fan to the venter assembly, (See Diagram C).
6. IMPORTANT: Make sure Cooling Fan air flow arrow is directed to inside of Venter, (See Diagram B). Insert (4) 8-32 x 1/2" studs
through fan flange, SS2 Venter Assembly and fan guard. Tighten (4) nuts to secure fan guard and fan to Venter Assembly.
7. Follow steps 4 - 1 in reverse order for reassembly.
8. Run SS2 & equipment through a couple of heating cycles to verify proper operation.
DIAGRAM A
Rev. A 09/06
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
(950-0020) 115 VAC FAN REPLACEMENT INSTRUCTIONS
DIAGRAM C
Copyright © 2006, Tjernlund Products, Inc. All rights reserved.
Important:
DIAGRAM B
Cooling Fan
air flow direction
P/N 8504073

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 950-0020 115V COOLING FAN 8504073 REV. A 0906 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TJERNLUND 950-0020 115V COOLING FAN 8504073 REV. A 0906

  • Page 1 8. Run SS2 & equipment through a couple of heating cycles to verify proper operation. Important: DIAGRAM A DIAGRAM B Cooling Fan air flow direction DIAGRAM C Rev. A 09/06 Copyright © 2006, Tjernlund Products, Inc. All rights reserved. P/N 8504073...
  • Page 2 FOR CRAWL SPACE VENTILATORS SEE INSTRUCTIONS BELOW Disconnect power or unplug 115 VAC power cord before servicing the crawl space ventilator. 1. Remove Crawl Space Ventilator from wall. Important: Note setting of dehumidistat (if equipped) so it can be reset when finished. Remove BLACK and WHITE motor leads from defective cooling fan.

This manual is also suitable for:

950-0020Sideshot ss2

Table of Contents