Digital Optical Monitoring - Dell PowerConnect B-FCX624 Hardware Installation Manual

Powerconnect b-fcx switch
Table of Contents

Advertisement

The output from this command appears below.
Table 20
TABLE 20
This Line...
Port
Speed
Local pair
Pair Length
Remote pair
Pair status

Digital optical monitoring

You can configure your device to monitor optical transceivers in the system, either globally or by
specified port. When this feature is enabled, the system monitors the temperature and signal
power levels for the optical transceivers in the specified ports. Console messages and syslog
messages are sent when optical operating conditions fall below or rise above the XFP, SFP, and
SFP+ manufacturer's recommended thresholds. For more information about digital optical
monitoring, refer to PowerConnect B-FCX Series Configuration Guide.
PowerConnect B-FCX Switch Hardware Installation Guide
53-1002267-01
PowerConnect# show cable-diag tdr 1/1/1
Port
Speed Local pair Pair Length Remote pair Pair status
--------- ----- ---------- ----------- ----------- -----------
1/1/1
1000M Pair A
Pair B
Pair C
Pair D
Syntax: show cable-diag tdr <port-num>
defines the fields shown in this output.
Cable statistics
Displays...
The port that was tested.
The current line speed of the port.
The local link name.
The cable length when terminated, or the distance to the point of fault when the line
is not up.
The remote link name.
The status of the link. This field displays one of the following:
Terminated: The link is up.
Shorted: A short is detected in the cable.
Open: An opening is detected in the cable.
ImpedMis: The impedance is mismatched.
Failed: The TDR test failed.
Troubleshooting network connections
<50M
Pair B
<50M
Pair A
<50M
Pair D
<50M
Pair C
Terminated