1
Hardware features
FIGURE 9
TABLE 6
LED
Link or Act LED (Link or
Activity)
NOTE
The two left ports on the Four-port 10Gbps SFP+ module do not pass regular Ethernet traffic by
default. The stack disable CLI command must be entered at the global level and the stack disable
CLI command must be configured on these two ports in order for them to pass regular traffic.
16/10 Gbps Ethernet CX4 stacking ports
The PowerConnect B-FCX624s and PowerConnect B-FCX648s devices include two 16/10 Gbps
Ethernet CX4 ports on the rear panel (the stacking ports). The device can perform data
transmission directly through copper links of up to 3 meters.
The Up Link and Down Link LEDs on the front panel indicate operational status. If the Up Link or
Down Link LED is on, the port is connected. If the Up Link or Down Link LED is off, no connection
exists, or the link is down.
Cable specifications for CX4 stacking ports
The following cable specifications apply to the CX4 stacking ports:
NOTE
PowerConnect B-FCX624-E, PowerConnect B-FCX624-I, PowerConnect B-FCX648-E, and
PowerConnect B-FCX648-I devices can be added to a stack using the first two ports on a four-port
10 Gbps SFP+ module (optional) using standard duplex LC cables.
Port, system, and power status LEDs for PowerConnect B-FCX624s and PowerConnect
B-FCX648s
PowerConnect B-FCX switches include a display panel for key system and port indicators that
simplifies installation and network troubleshooting. The LEDs, which are located on the front panel
for easy viewing, are shown below and described in the following tables.
8
Four-port 10 Gbps SFP+ module
Four-port 10 Gbps SFP+ module status LEDs
Condition
On or flashing Green
Off
Support for 802.3ak or 10 Gbps Ethernet CX4 standard and 16 Gbps inter-unit stacking (up to
8 units in a stack)
Support for cables up to 3 meters in length
Requires latch-style receptacle or SFF-8470 plug
X1
X2
X3
X4
FCX-4XG
Status
Port has a valid link at 10 Gbps. Flashing indicates activity.
The link is down.
PowerConnect B-FCX Switch Hardware Installation Guide