IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS
DO NOT ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE
This system requires a minimum 18-square inches (per side) of cross ventilation.
Failure to provide proper ventilation will void the warranty.
Warning: For Outdoor Use Only
Propane Models
FPB-20SBSAWS-P
FPB-26SBSAWS-P
FPB-32SBSAWS-P
FPB-38SBSAWS-P
INSTALLATION PRECAUTION:
PN#90214
DO NOT DISCARD. THIS MANUAL
HAS IMPORTANT OPERATING AND
MAINTENANCE INSTRUCTIONS.
LEAVE WITH THE HOMEOWNER.
MODEL:
SERIAL #:
Certified by Lab Test Certification for USA and
Canada. Meets: ANSI Z21.972014, CSA C22.2 No.
3-M1998 (R2014).
Square Flat Disc
Description
20" Square Pan with 16" Spur Burner
26" Square Pan with 22" Spur Burner
32" Square Pan with 31" Spur Burner
38" Square Pan with 36" Spur Burner
25" Square Flat Disc with 22" Spur Burner
30" Square Flat Disc with 22" Spur Burner
34" Square Flat Disc with 31" Spur Burner
40" Square Flat Disc with 36" Spur Burner
46" Square Flat Disc with 36" Spur Burner

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FPB-46SFBSAWS-P and is the answer not in the manual?

Questions and answers

Summary of Contents for Firegear FPB-46SFBSAWS-P

  • Page 1 34” Square Flat Disc with 31” Spur Burner FPB-40SFBSAWS-N FPB-40SFBSAWS-P 40” Square Flat Disc with 36” Spur Burner FPB-46SFBSAWS-N FPB-46SFBSAWS-P 46” Square Flat Disc with 36” Spur Burner Outdoor Square Pan & Flat Disc Fire Pits with All Weather System (AWS)
  • Page 2: Carbon Monoxide Hazard

    State of California to cause cancer, birth defects and other reproductive harm and Carbon Monoxide which is known to the State of California to cause birth defects or other reproductive harm. (For more information go to: www.p65Warnings.ca.gov.) Firegear Outdoors All Weather Ignition System (AWS) REV. A Page 2...
  • Page 3: Table Of Contents

    This drying out period should be no less than 30 minutes. Continue monitoring the flame from distance to ensure that all popping has ceased before fully enjoying the fire. Firegear Outdoors All Weather Ignition System (AWS) REV. A Page 3...
  • Page 4: Specifications

    Btu’s. As a result your Btu’s may FPB-46SFBSAWS-N 25/34” FPB-46SFBSAWS-P 250,000 (73.26kW) vary slightly from Table 2 Table 2 Btu Specifications for Burner Spur by Firegear Outdoors specifications. Pressure Min. Inlet 3.5” WC (⅛ PSI) (0.87kPa) 8.0” WC (⅓ PSI) (1.99kPa) Max.
  • Page 5: Preparing A Non Combustible Structure

    290,000 Btu’s and it is shipped this manual for a Firegear burner. NOTE: Depending on as a Natural Gas (NG) model. It must be installed with a venting locations, do not place fire pit directly on grass, burner pan, burner, orifice and installed into a dirt, or rocks that could prevent proper ventilation.
  • Page 6: Natural Gas : Pipe Sizing Chart

    This chart is for reference only, we recommend you consult with a Licensed Plumber/Gas Fitter or NFPA54 (National Fuel Gas Code - current edition) for more details. Table 4 Gas Pipe Sizing Chart Firegear Outdoors All Weather Ignition System (AWS) REV. A Page 6...
  • Page 7: Carton Contents - Removing Fire Pit From Carton

    Pan lip or disc edge (included with fire pit) must be unobstructed so it can be lifted out of the fire pit for servicing. Fig. 5 Hardware bag contents. Firegear Outdoors All Weather Ignition System (AWS) REV. A Page 7...
  • Page 8: Gas Information

    Natural gas. To convert to Propane (LP) gas, the secondary pilot orifice must be changed. Power Supply - Firegear Outdoors offers two power supplies for use with the fire features. Each power Manual Shut-off/Key Valve - Is there a manual shut-off or...
  • Page 9: Power Supply Location For Single Installation

    Fig. 5 Example of a single fire feature install with power supply and switch contained within the enclosure, when applicable. Note: Must be 10-feet or more from a pool/spa for this installation. See additional illustration on page 10, Fig. 8. Firegear Outdoors All Weather Ignition System (AWS) REV. A Page 9...
  • Page 10: Installing Key Valve

    The red sleeve from the Non-Combustible adapter connects to the other side of the switch. See Figs. Wall Material 23 and 24 on page 15. Primary Gas Supply Fig. 20 Key valve components Firegear Outdoors All Weather Ignition System (AWS) REV. A Page 10...
  • Page 11: Media Installation

    Do NOT cover the top of mesh pilot hood with any rock or glass. It must be free an any debris to operate properly. Mesh Pilot Hood Media Fig. 22 Media placement around pilot hood. Firegear Outdoors All Weather Ignition System (AWS) REV. A Page 11...
  • Page 12: Wiring Diagrams

    WIRING DIAGRAM FOR OPTIONAL REMOTE CONTROL Valve Box Weather Proof Power Wire to Valve GFI Box FG-1420-A-OD Receiver LEARN GOE-30VDC Power Supply Fig. 23 Wire diagram of AWS system with optional1420-A remote control. Firegear Outdoors All Weather Ignition System (AWS) REV. A Page 12...
  • Page 13: Operation & Lighting

    1. Turn the fire feature OFF by pressing the opposite button on the rocker switch. 2. If you are no longer burning the fire pit until another time, we recommend turning the key valve to OFF position. Firegear Outdoors All Weather Ignition System (AWS) REV. A...
  • Page 14: Replacements Parts

    To 120VAC To Fire Attach Ground GFI Power Feature(s) Junction box is 6” deep (12-gauge wire & strain relief (12-gauge wire & strain relief supplied by installer) supplied by installer) Firegear Outdoors All Weather Ignition System (AWS) REV. A Page 14...
  • Page 15: Replacement Parts List

    2-pin Igniter Connector (pilot lead has two white wires under insulation) 2-pin Thermopile Connector (pilot lead has a red and white wire under insulation) Flared Pilot Connection Compression Pilot Connection Firegear Outdoors All Weather Ignition System (AWS) REV. A Page 15...
  • Page 16: Troubleshooting

    Use a multi-meter to check resistance. No resistance or resistance greater than 8 ohms indicates a defective igniter. Page 27 valve reference shows the igniter and thermopile 2-pin connections for testing. Firegear Outdoors All Weather Ignition System (AWS) REV. A Page 16...
  • Page 17 Thermopile is not defective the only thing left is a Defective Controller inside the valve box. If you have a Defective Controller the only way to fix it is to replace it. Firegear Outdoors All Weather Ignition System (AWS) REV. A...
  • Page 18 Often this will result in a small flame that continues to burn on the Main Burner after the feature has been turned OFF. Firegear Outdoors All Weather Ignition System (AWS) REV. A Page 18...
  • Page 19: Optional Accessories

    Cover/Lid Junction Box NOTE: See the Firegear Outdoors catalogue for a additional accessories not shown above. FIRE PIT MAINTENANCE 1. The fire pit should be inspected and cleaned before initial use at least annually by a qualified field service person.
  • Page 20: Warranty

    FIREGEAR LIMITED WARRANTY - 2021 Firegear Outdoors hereby warrants to the end user that products will be free from material and workmanship defects that prevent safe and correct operation of the product. The warranty commences from date of sale to the end user for the following period: CONSUMER RESIDENTIAL APPLICATIONS –...
  • Page 21 • LIFETIME WARRANTY - CONSTRUCTION AND MANUFACTURER DEFECTS • LIFETIME WARRANTY - STAINLESS STEEL COMPONENTS (LIDS, STAINLESS STEEL COVERS) • ONE (1) YEAR WARRANTY – ESTOP1-OH, ESTOP2-5H WINDSHIELDS, HOSES AND REGULATORS Firegear Outdoors All Weather Ignition System (AWS) REV. A Page 21...
  • Page 22 The manufacturer may request defective products returned with an RMA (Return Merchandise Authorization) issued by Firegear Outdoors for specific products, which is considered to be the nature of the defect and or warranty claim. Product to be returned should; be packed so as not to incur damages during transportation.
  • Page 23 Firegear Outdoors 14520 Delta Lane, Suite 105 Huntington Beach, CA 92647 Web Site: www.firegearoutdoors.com Manual changes often occur, ensure to check the Firegear Outdoor website for any recent updates and warranty information. Firegear Outdoors All Weather Ignition System (AWS) REV. A...