GE NX-1308E - Caddx 8 Zone LED Keypad Installation And Startup Manual page 48

Networx series
Table of Contents

Advertisement

LOC
PG
84-87
32
RESERVED
88
32
PARTITION 1, ACCOUNT CODE
89
32
PARTITION 2, ACCOUNT CODE
90
32
PARTITION 2, FEATURE AND REPORTING SELECTION
Segment #1
1
2
3
4
5
6
7
8
91
32
PARTITION 2 ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1)
Segment #2 (Exit Time #1)
Segment #3 (Entry Time #2)
Segment #4 (Exit Time #2)
92
32
PARTITION 3, ACCOUNT CODE
93
33
PARTITION 3, FEATURE AND REPORTING SELECTION
1
Quick Arm
2
Re-Exit
3
Auto Bypass
4
Silent Panic
5
Audible Panic
6
Auxiliary 1
7
Auxiliary 2
8
Multi Keypress Tamper
94
33
PARTITION 3 ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1)
Segment #2 (Exit Time #1)
Segment #3 (Entry Time #2)
Segment #4 (Exit Time #2)
95
33
PARTITION 4, ACCOUNT CODE
96
33
PARTITION 4, FEATURE AND REPORTING SELECTION
Segment #1
1
Quick Arm
2
Re-Exit
3
Auto Bypass
4
Silent Panic
5
Audible Panic
6
Auxiliary 1
7
Auxiliary 2
8
Multi Keypress Tamper
97
33
PARTITION 4, ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1)
Segment #2 (Exit Time #1)
Segment #3 (Entry Time #2)
Segment #4 (Exit Time #2)
98
33
PARTITION 5, ACCOUNT CODE
48
DESCRIPTION
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
Segment #1
Segment #2
1
LED Extinguish enable
2
Require user code for bypassing zones
3
Bypass sounder alert
4
AC Power/Low Battery sounder alert
5
Enables Bypass toggle
6
Enables Silent Auto Arm
7
Enables Automatic Instant
8
Reserved
Segment #2
1
LED Extinguish enable
2
Require user code for bypassing zones
3
Bypass sounder alert
4
AC Power/Low Battery sounder alert
5
Enables Bypass toggle
6
Enables Silent Auto Arm
7
Enables Automatic Instant
8
Reserved
Segment #2
1
LED Extinguish enable
2
Require user code for bypassing zones
3
Bypass sounder alert
4
AC Power/Low Battery sounder alert
5
Enables Bypass toggle
6
Enables Silent Auto Arm
7
Enables Automatic Instant
8
Reserved
DEFAULT
0-0-0-0
RESERVED
10-10-10-10-10-10
_ _ _ _ _ _
10-10-10-10-10-10
_ _ _ _ _ _
Segment #3
1
Open/Close
2
Bypass
3
Restore
4
Trouble
5
Tamper
6
Cancel
7
Recent Closing
8
Exit Error
0
0
0
0
10-10-10-10-10-10
_ _ _ _ _ _
Segment #3
1
Open/Close
2
Bypass
3
Restore
4
Trouble
5
Tamper
6
Cancel
7
Recent Closing
8
Exit Error
0
0
0
0
10-10-10-10-10-10
_ _ _ _ _ _
Segment #3
1
Open/Close
2
Bypass
3
Restore
4
Trouble
5
Tamper
6
Cancel
7
Recent Closing
8
Exit Error
0
0
0
0
10-10-10-10-10-10
_ _ _ _ _ _
DATA
_
_
_
_
_
_
_
_
_
_
_
_
NX-8 Control

Advertisement

Table of Contents
loading

This manual is also suitable for:

Networx nx-8

Table of Contents