Nx-8 Programming Worksheets - GE NX-1308E - Caddx 8 Zone LED Keypad Installation And Startup Manual

Networx series
Table of Contents

Advertisement

(Factory defaults for segments are in bold italics text and "Quick Start" locations are identified with the L symbol.)
LOC
PG
L
0
13 PHONE #1
L
1
13 PHONE #1, ACCOUNT CODE
L
2
13 PHONE #1, REPORTING FORMAT
L
3
13 PHONE #1, DIAL ATTEMPTS
BACKUP CONTROL
4
14
PHONE #1, SELECTING EVENTS TO REPORT TO PHONE #1
Segment #1 (Circle Numbers To Program)
1
Alarms and Restores
2
Open/Close
3
Bypass
4
Zone Trouble
5
Power Trouble (AC Failure or Low Battery)
6
Siren & Telephone Fault
7
Test Reports
8
Program, Download, & Log Full
5
15
PHONE #1, SELECTING WHICH PARTITIONS REPORT TO PHONE #1
Segment #1
1
Partition #1
2
Partition #2
3
Partition #3
4
Partition #4
5
Partition #5
6
Partition #6
7
Partition #7
8
Partition #8
L
6
15
PHONE #2
L
7
15
PHONE #2, ACCOUNT CODE
L
8
15 PHONE #2, REPORTING
FORMAT
9
15
PHONE #2, DIAL ATTEMPTS
BACKUP CONTROL
10
16
PHONE #2, SELECTING EVENTS TO REPORT TO PHONE #2
Segment #1 (Circle Numbers To Program)
1
Alarms and Restores
2
Open/Close
3
Bypass
4
Zone Trouble
5
Power Trouble (AC Failure or Low Battery)
6
Siren & Telephone Fault
7
Test Reports
8
Program, Download, & Log Full
11
16
PHONE #2, SELECTING WHICH PARTITIONS REPORT TO PHONE #2
Segment #1
1
Partition #1
2
Partition #2
3
Partition #3
4
Partition #4
5
Partition #5
6
Partition #6
7
Partition #7
8
Partition #8
NX-8 Control

NX-8 PROGRAMMING WORKSHEETS

DESCRIPTION
(Circle Numbers To Program)
(Circle Numbers To Program)
DEFAULT
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
10 - 10 - 10 - 10 - 10 - 10
0
8
0
Segment #2 (Circle Numbers To Program)
1
Tampers
2
Short Circuit & Ground Fault
3
Sensor Lost
4
Sensor Low Battery
5
Expander Trouble
6
Failure To Communicate
7
Reserved
8
Reserved
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
10 - 10 - 10 - 10 - 10 - 10
0
8
0
Segment #2 (Circle Numbers To Program)
1
Tampers
2
Short Circuit & Ground Fault
3
Sensor Lost
4
Sensor Low Battery
5
Expander Trouble
6
Failure To Communicate
7
Reserved
8
Reserved
PROGRAMMING DATA
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
_ _ _ _ _ _
_
_
_
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
_ _ _ _ _ _
_
_
_
39