LOCATION 18 - CUSTOM COMMUNICATOR FORMAT (See locations 2, 8, &14)
Segment 1:
1 = On for 1800hz transmit; Off for 1900hz.
2= On for 2300hz handshake; Off for 1400hz.
3= On for cksum parity; Off for double round parity.
4= On for 2 digit event code; Off for 1 digit event code.
5= Reserved.
6= Reserved.
7= On for 20 p.p.s.; Off for 10 or 40 p.p.s.
8= On for 10 p.p.s.; Off for 20 or 40 p.p.s.
Segment 2 :
1= On for pager format (no handshake required).
2= On for 1400/2300 handshake.
3= Reserved
4= Reserved.
5= On for Contact ID.
6= On for SIA.
7= On for Contact ID or 4+3.
8= On for DTMF.
Segment 3 & 4: Reserved.
L
LOCATION 19 - DOWNLOAD ACCESS CODE (8 segments, numerical data)
Location 19 contains the eight digit access code the NX-8 must receive from the downloading software before the
panel will permit downloading to occur. The factory default code is 84800000.
L
LOCATION 20 - NUMBER OF RINGS TO ANSWER (1 segment, numerical data)
Location 20 contains the number of rings to answer for a download. Enter a number from A0" (disabled) to "15".
Factory default is "8" and the NX-8 will answer on 8 rings.
L
LOCATION 21 - DOWNLOAD CONTROL (1 segment, feature selection data)
Location 21 contains the feature selections for the controlling of download sessions. The following features can be
enabled or disabled using this location. (See the feature definitions beginning on page 5)
Segment 1:
1 -
On enables two call answering machine defeat.
2 -
On enables tone sniff answering machine defeat.
3 -
On requires call back before download session.
4 -
Shutdown (can only be viewed from the keypad, must be changed through downloading).
5 -
On locks all local programming. (can only be viewed from the keypad, must be changed through
downloading)
6 -
On locks programming of all locations associated with the communicator (can only be viewed from the
keypad, must be changed through downloading)
7 -
On locks out download section. (can only be viewed from the keypad, must be changed through
downloading. If "On", locations 19 - 22 cannot be viewed from the keypad; can only be viewed
from the keypad when "Off".)
8 -
On enables call back at auto test interval.
L
LOCATION 22 - DOWNLOAD CALL BACK NUMBER (20 segments, numerical data)
If a telephone number is programmed into this location, and "Require Callback" is enabled in location 21, the control
panel will hang up for approximately 36 seconds (ensuring that the calling party has disconnected), and then call back.
If tone dialing is desired, program a "15" in the segment where tone dialing should begin. If the entire number should
be tone dialing, program an A15" in the first segment. Four-second delays can be obtained anywhere in the sequence
by programming a "13" in the appropriate delay location. WARNING: THE CALLBACK PHONE NUMBER SHOULD
ALWAYS BE REVIEWED FOR ACCURACY BEFORE DISCONNECTING.