LOC
PG
108
34
PARTITION 8, FEATURE AND REPORTING SELECTION
Segment #1
1
Quick Arm
2
Re-Exit
3
Auto Bypass
4
Silent Panic
5
Audible Panic
6
Auxiliary 1
7
Auxiliary 2
8
Multi Keypress Tamper
109
35
PARTITION 8, ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1)
Segment #2 (Exit Time #1)
Segment #3 (Entry Time #2)
Segment #4 (Exit Time #2)
110
35
ZONE TYPE 1 ALARM EVENT CODE
111
35
ZONE TYPE 1 CHARACTERISTIC SELECT
Segment #1 (Circle numbers to program)
1
Fire (enable for fire zone).
2
24 Hour (enable for non-fire 24 hour
zone).
3
Keyswitch zone.
4
Follower (enable for burg zones that are
instant during non-entry times).
Segment #2 (Circle numbers to program)
1
Keypad audible on alarm.
2
Yelping siren on alarm.
3
Temporal siren on alarm.
4
Chime.
Segment #3 (Circle numbers to program)
1
Fast Loop Response.
2
Double End of Line Tamper zone.
3
Trouble zone (Day zone).
4
Cross Zone.
THE DEFAULTS LISTED IN THE ODD NUMBERED LOCATIONS BELOW REPRESENT THE THREE SEGMENTS OF
EACH OF THOSE LOCATIONS. USE THE THREE SEGMENT CHARTS FROM LOCATION 111 TO UNDERSTAND
THESE DEFAULTS.
112
35
ZONE TYPE 2 ALARM EVENT CODE
113
35
ZONE TYPE 2 CHARACTERISTIC SELECT
114
35
ZONE TYPE 3 ALARM EVENT CODE
115
36
ZONE TYPE 3 CHARACTERISTIC SELECT
116
36
ZONE TYPE 4 ALARM EVENT CODE
117
36
ZONE TYPE 4 CHARACTERISTIC SELECT
118
36
ZONE TYPE 5 ALARM EVENT CODE
119
36
ZONE TYPE 5 CHARACTERISTIC SELECT
120
36
ZONE TYPE 6 ALARM EVENT CODE
121
36
ZONE TYPE 6 CHARACTERISTIC SELECT
122
36
ZONE TYPE 7 ALARM EVENT CODE
123
36
ZONE TYPE 7 CHARACTERISTIC SELECT
124
36
ZONE TYPE 8 ALARM EVENT CODE
125
36
ZONE TYPE 8 CHARACTERISTIC SELECT
126
36
ZONE TYPE 9 ALARM EVENT CODE
50
DESCRIPTION
Segment #2
1
LED Extinguish enable
2
Require user code for bypassing zones
3
Bypass sounder alert
4
AC Power/Low Battery sounder alert
5
Enables Bypass toggle
6
Enables Silent Auto Arm
7
Enables Automatic Instant
8
Reserved
5
6
7
8
5
6
7
8
5
6
7
8
DEFAULT
Delay 1 zone (enable to follow Timer 1 Entry/Exit
times).
Delay 2 zone (enable to follow Timer 2 Entry / Exit
times).
Interior (Enable for auto bypass or stay arming).
Local Only (enable if zone is not to be reported).
Bypassable.
Group Shunt.
Force armable.
Entry Guard.
Dialer Delay zone.
Swinger zone.
Restore reporting.
Listen-In.
2-125-78
5-1245-5678
45-125-5678
457-125-5678
0-1245-5678
2-0-78
1-13-378
DATA
Segment #3
1
Open/Close
2
Bypass
3
Restore
4
Trouble
5
Tamper
6
Cancel
7
Recent Closing
8
Exit Error
0
_
0
_
0
_
0
_
8
_
2
_
7
_
5
_
5
_
4
_
0
_
1
_
7
_
NX-8 Control