Download Print this page

Teac CD-RW901SL Specification page 34

Control i/o connector rs-232c protocol specification

Advertisement

MECHA STATUS RETURN
This is the return command for the command "MECHA STATUS SENSE [50]."
It returns the current operating status of the mechanism.
Command
D0
Machine ID
0
Data
2 bytes
Data 1
Data 2
0
0
0
1
0
2
1
0
1
1
1
2
8
0
8
1
8
2
8
3
Request/Preset MECHA STATUS SENSE [50]
ISRC RETURN
This is the return command for the command "ISRC SENSE [53]."
It returns the ISRC code for the current track number.
Command
D3
Machine ID
0
Data
12 bytes
Data 1 – Data
12
Request/Preset ISRC SENSE [53]
TRACK No. RETURN
This is the return command for the command "TRACK No. SENSE [55]."
It returns whether the current track number and EOM are shown.
If Group mode is on, the group number is returned.
Command
D5
Machine ID
0
Data
6 bytes
Description
Data 1
EOM Status
Data 2
Data 3
Tens digit
Data 4
Ones digit
Data 5
Thousands
digit
Data 6
Hundreds
digit
・ The group number is returned with 1000 added.
Request/Preset TRACK No. SENSE [55]
Description
No Disc
Tray
Open
Stop
Play
Ready On
Monitor
Record
Record Ready
TOC Writing
Description
Remarks
Single-byte alphanumeric characters
ISRC code
(If no ISRC code is stored, returns all zeros.)
Remarks
00:EOM indication not shown
01:EOM is displayed
0000
0001 – 0999
1000
1001 - 1099
TASCAM MD-CD1 RS-232C Protocol Specification
Remarks
No disc is inserted
Tray is being opened or closed
Tray is open
Stopped
Playing
Play-ready mode
Input monitor status (no disc is inserted)
Recording
Record-ready mode
Writing the TOC / Erasing or Finalizing
Stopped, and track is not cued, etc.
Track number
Group mode is on, but no group has been created
Group number
33
TEAC Corporation

Advertisement

loading