Control i/o connector rs-232c protocol specification

Advertisement

REMOTE/LOCAL SELECT
Enables or disables key operations on the controlled device's own panel.
A return command is returned only if Sense [FF] is specified.
Command
4C
Machine ID
0
Data
2 bytes
Data 1
Data 2
0
0
0
1
F
F
・ If data other than the above is received, the CD-RW901 will transmit ILLEGAL [F2].
Return
REMOTE/LOCAL SELECT RETURN [CC]
PLAY MODE SENSE
Requests that the status of the controlled device's Play mode be returned.
Command
4E
Machine ID
0
Data
none
Return
PLAY MODE RETURN [CE]
MECHA STATUS SENSE
Requests that the status of the controlled device's mechanism be returned.
Command
50
Machine ID
0
Data
none
Return
MECHA STATUS RETURN [D0]
ISRC SENSE
Requests that the ISRC of the current track be returned.
Command
53
Machine ID
0
Data
none
Return
ISRC RETURN [D3]
TRACK No. SENSE
Requests that the current track number be returned.
Command
55
Machine ID
0
Data
none
Return
TRACK No. RETURN [D5]
DISC STATUS SENSE
Requests that the presence or absence of a disc and the type of disc be returned.
Command
56
Machine ID
0
Data
none
Return
DISC STATUS RETURN [D6]
Description
Remarks
Remote
Only remote operation via RS-232C and wired remote
control will be enabled. Key operations on the device's own
panel will be disabled.
Local
Remote operation and key operations on the device's own
panel will be enabled.
Sense
Requests that the preset content be returned.
TASCAM MD-CD1 RS-232C Protocol Specification
22
TEAC Corporation

Advertisement