Download Print this page

Teac CD-RW901SL Specification page 9

Control i/o connector rs-232c protocol specification

Advertisement

MECHA STATUS SENSE
RECORD (Record)
3.5. Command details
The commands, data, and machine IDs described here are characters (ASCII).
A command is two character bytes, a machine ID is one character byte, and each item of data is an
individual character byte.
The CD-RW901 can use the following track numbers and group numbers. However if a number not
existing on the disc is specified, it will be considered an invalid command.
Track number (audio CD)
Track number (MP3 CD)
INFORMATION REQUEST
Requests the controlled device to return information such as the software version.
Command
0F
Machine ID
0
Data
none
Return
INFORMATION RETURN [8F]
STOP
Puts the controlled device in STOP mode, and defeats input monitor mode.
Command
10
Machine ID
0
Data
none
Return
none
PLAY
Puts the controlled device in PLAY mode, or in RECORD mode if it is in record-ready mode.
Command
12
Machine ID
0
Data
none
Return
none
RECORD
Puts the controlled device in RECORD-READY mode. If it is currently recording, assigns a track. If
the state is currently No Disc, puts the controlled device in Input Monitor mode.
Command
13
Machine ID
0
Data
2 bytes
Data 1
Data 2
0
1
0
2
0
3
・ If data other than the above is received, the CD-RW901 will transmit ILLEGAL [F2].
Return
none
CHANGED STATUS
<-
->
MECHA
<-
RETURN
->
CHANGES STATUS
<-
maximum 99
Description
Remarks
Record Ready
Puts the device in record-ready mode.
Track Mark
Assigns a track during recording.
Input Monitor
Puts the device in Input Monitor mode while stopped.
TASCAM MD-CD1 RS-232C Protocol Specification
Transmitted
record-ready status
STATUS
Returns record-ready status
Transmitted
record status
maximum 999
8
when
entering
when
entering
TEAC Corporation

Advertisement

loading