Download Print this page

Teac CD-RW901SL Specification page 11

Control i/o connector rs-232c protocol specification

Advertisement

SHUTTLE
Puts the controlled device in SHUTTLE mode.
SHUTTLE mode will be maintained until a command such as STOP, PLAY, or READY is received.
Command
16
Machine ID
0
Data
2 bytes
Data 1
Data 2
0
0
0
1
・ If data other than the above is received, the CD-RW901 will transmit ILLEGAL [F2].
Return
none
TRAY
Opens or closes the tray of the controlled device.
Command
18
Machine ID
0
Data
none
Return
none
SKIP
Causes the controlled device to skip tracks.
After skipping, the device will maintain the mode in which it was when the operation began.
Command
1A
Machine ID
0
Data
2 bytes
Data 1
Data 2
0
0
0
1
1
0
1
1
・ If data other than the above is received, the CD-RW901 will transmit ILLEGAL [F2].
Return
none
CALL
Causes the controlled device to locate to the call point and enter playback-ready mode.
Command
1D
Machine ID
0
Data
none
Return
none
Description
Remarks
Shuttle
Shuttles in the forward direction.
Forward
Shuttle
Shuttles in the backward direction.
Reverse
Description
Remarks
Track Skip Next
Skips to the next track.
Track
Skip
If the current position is at the beginning of a track,
Previous
skips to the beginning of the previous track. If the
current position is not at the beginning of a track, skips
to the beginning of the current track..
Index Skip Next
Skips to the next index.
Index
Skip
If the current position is index 2 or higher, skips to the
Previous
beginning of the previous index.
TASCAM MD-CD1 RS-232C Protocol Specification
10
TEAC Corporation

Advertisement