Control i/o connector rs-232c protocol specification

Advertisement

SYNC REC LEVEL PRESET
Sets the Sync Rec Level of the controlled device.
A return command is returned only if Sense [FF] is specified.
The SYNC REC MODE setting is made by the command "SYNC REC SELECT [38]."
Command
28
Machine ID
0
Data
2 bytes
Data 1
Data 2
0
0
0
1
0
2
0
3
0
4
0
5
0
6
0
7
0
8
F
F
・ If data outside the above range is received, the CD-RW901 will return ILLEGAL [F2].
Return
SYNC REC LEVEL RETURN [A8]
TEXT PRESET
Specifies a title for the controlled device of up to 80 single-byte alphabetical or katakana characters.
To obtain the assigned title, transmit the command "TITLE SENSE [59]."
Command
29
Machine ID
0
Data
4 bytes~84 Bytes
Data 1
Data 2
Data 3
Data 4
Data 5 – Data
84
・ If a track number not existing on the disc is specified, the CD-RW901 will transmit ILLEGAL
[F2].
・ The title is between 0 bytes and 80 bytes. The characters up to the last one before CR will be
used as the specified title.
Return
TEXT PRESET ACKNOWLEDGE [A9]
Description
Remarks
Preset –24dB
Preset –30dB
Preset –36dB
Preset –42dB
Preset –48dB
Preset –54dB
Preset –60dB
Preset –66dB
Preset –72dB
Sense
Requests that the currently preset level be returned.
Description
Remarks
Tens
digit
of
specified number
Ones
digit
of
specified number
0000
0001 – 0099
Thousands digit of
specified number
Hundreds digit of
specified number
Title
Single-byte alphanumeric characters
TASCAM MD-CD1 RS-232C Protocol Specification
Specify the disc title
Specify a track title
14
TEAC Corporation