Technical Specifications; Renewing The Hygienic Microfilter; Inspecting And Cleaning The Accessories; Storing The Cleaner - Kärcher SE 2001 Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9

Renewing the hygienic microfilter

(Order no. 6.904-143)
The hygienic microfilter should be replaced
whenever the paper filter bag is renewed for
the fifth time – earlier if required.
■ Push cover panels towards rear
■ Mount hygienic microfilter onto cover
panel,and refit both to cleaner.

Inspecting and cleaning the accessories

Check the following accessories at regular
intervals to ensure that they are not full of dirt,
blocked or damaged:
– all suction and spraying nozzles
– spraying and suction hose with handle
– suction tubes
– rubber lip and bristles on hard-surface
adapter
– suction filter in detergent reservoir
– Parts 1 and 2 must be movable.
■ Rinse parts with water if required.
Cleaning the device
■ Fill the cleaning agent container with
approximately 1 litre of clear water.
■ Hold the spray-ex nozzle into a large
container or the shower tub.
■ Switch on the spraying pump
the appliance with clear water until it has
been consumed.
■ Switch on the suction turbine
vacuum the sprayed water to clean the
suction tubes.
■ Empty the dirt container, rinse the dirt
container and the accessories and let dry.

Storing the cleaner

■ Place accessories in holder on cleaner.
■ Wind mains cable and spraying and suction
hose into coils, and wrap them round
accessories.
Note: To release the coupling unit of the spraying
and suction hose, press the two housing parts
together and remove the coupling.
Power supply
Mains fuse (slow)
Power:
Suction turbine
Air flow
Vacuum
Capacity, wet vacuuming
Capacity, filter bag
Spraying rate
Capacity, fresh water
Capacity, dirty water
Length
Width
Height
Weight
Size of accessory connection
Sound pressure level
Protection class
Mains cable:
Length
Type
, and rinse
, and
English
230 - 240 V
1~ 50/60 Hz
10 A
1440 Watt
P
1400 Watt
max
P
1200 Watt
nom
74 L/s
200 mbar
11 L
12 L
1 L/min
5 L
6 L
370 m m
290 m m
470 m m
approx. 7 kg
35/60 m m
77 dB(A)
I I
5 m
H 05 VV – F 2x1
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Se 3001Se 3001 plus

Table of Contents