READY 00:00
WALK TEST
USER SETTINGS
INSTALLER MODE
INSTALLER MODE
ENTER CODE
[installer code]
1. NEW INSTL CODE
2. ENROLLING
3. DEFINE ZONES
4. DEFINE PANEL
5. DEFINE COMM
8. DEFINE OUTPUTS
*
Upon selecting any one of the 3 options (zone a, b and c) you may enter a zone number and then select "disable", "turn on", "turn
off", "pulse active" or "toggle".
The currently saved option is displayed with a dark box at the right side. To review the options, repeatedly click
**
until the desired option is displayed, then click

4.9 DEFINE VOICE

DEFINE
VOICE
is
PowerMaxComplete that includes "voice" feature.

4.9.1 Record Speech

This mode allows you to record short-duration speech
messages for the following purposes:
• House identity is a message announced automatically
when events are reported to private telephones.
• 4 User Names can be recorded and assigned to users
numbered 5-8. In case of event, the relevant user
name will be added to the message that will be
reported via the telephone.
D-302754
(*)
PGM: BY ARM AWAY
disable
turn on
turn off
pulse active
PGM: BY DELAY
disable
turn on
turn off
pulse active
Figure 4.8 - Define Outputs Flow Chart
optional
-
applicable
DEFINE PGM
PGM PULSE TIME
pulse time 2s
pulse time 30s
(**)
pulse time 2m
pulse time 4m
PGM: BY ARM HOME
disable
turn on
turn off
pulse active
PGM: BY KEYFOB
disable
turn on
(*)
turn off
pulse active
toggle
(a dark box will be displayed at the right side).
only
in
• 5 custom zone names can be recorded and assigned
to specific zones. These names are useful if none of
the 26 fixed zone names are found suitable for a
certain zone (see Fig. 4.3).
• Edit custom zone names enables you to edit the
names that have been assigned to zones.
The recording process is shown below.

4.9.2 Voice Box Mode

This mode allows you to determine whether two-way voice
communication is to be sounded either via the optional
external speech box, via the PowerMaxComplete, or via both.
Options: No Voice Box, Voice Box Only or Voice Box
Mixed.
PGM GENERAL DEF
DEFINE INT/STRB
internal siren
strobe
Select "start"/"stop"and
enter the desired time.
PGM: BY DISARM
disable
turn on
turn off
pulse active
PGM: BY ZONES
a - zone
c - zone
b - zone
(SELECT BY
OR
)
x - zone
Z: _ _
(ENTER ZONE NUMBERS)
disable
turn on
turn off
pulse active
toggle
LOCKOUT TIME
start - HH:MM A
stop - HH:MM A
TIME - 00:00 A
PGM: BY MEMORY
disable
turn on
turn off
pulse active
PGM: BY LINE FAIL
by line fail no
by line fail yes
button