CONNECT WIRED DETECTORS AS FOLLOWS:
ZONE 29 /
ZONE 29 /
(*)
ZONE 30
GND
12V
ZONE 30
2.2 kΩ
Power
TAMP
Alarm
Alarm
N.C.
N.C.
N.C.
Detector with
Detector without
Tamper switch
Tamper switch
Notes for EXPANDER module wiring:
*
Zone 29/GND and Zone 30/GND terminals can be
connected to a normally closed contact of a detector,
switch (for example a Tamper switch of any device), or
a pushbutton, via a 2.2 K
can be used to supply 12V (up to 36mA) to a
detector (if necessary).
**
The EXT terminal can be used to trigger an external siren.
The INT terminal can be programmed for an "internal
siren" or "strobe" (see DEFINE OUTPUTS - DEFINE
INT/STRB in par. 4.8).
The 12V and "GND" terminals can be connected to a
siren (for constant DC power supply).
6
ZONE 29 & SIREN WIRING
OPTIONAL EXPANDER MODULE
ZONES, SIRENS, AUDIO BOX AND WIRED DETECTORS WIRING
Note
The EXPANDER module
is an optional module.
If this optional module is
not used, a small 4-
terminal strip is used
instead (2 terminals for
zone 29 and 2 terminals
for siren).
(*)
GND
12V
Note
Regarding zones 29 & 30, the Control
Panel "sees" a specific resistance
according to the event, as follows:
Power
Normal (no alarm & no tamper): 2.2 k Ω
Alarm event: 4.4 k Ω
Tamper event: Infinite resistance
Ω
resistor. The 12V terminal
MAGNETIC CONTACT
OR ANY OTHER
CONTACT
(NOT A DETECTOR)
MIC
SPK
VOICE BOX
Figure 3.2 - Wiring
WARNING! When plugging terminals back into place, be
sure to align them carefully with the pins on the PCB.
Misaligned or reverse insertion of terminals may damage
internal PowerMaxComplete circuits!
IMPORTANT! The terminals for internal and external
sirens are DC outputs intended for 12V sirens. Connecting
a loudspeaker to any of these outputs will cause a short
circuit and will damage the unit.
2.2 kΩ
Alarm
N.C.
EXPANDER
GND
12V
PGM
EXT.-
SRN+ IN.-
Z29 GND Z30
SITE
INTERNAL
SIREN OR
STROBE
SITE EXTERNAL
SIREN MG441PDS
OR SIMILAR
12 VDC SIREN
SITE EXTERNAL SIREN
MG ELECTRONICS
MG441PDS OR SIMILAR
12 VDC SIREN
Caution:
When using the Expander,
the internal siren and
Zone 29 must be wired
via the Expander
and not via the
control panel.
D-302754